Abbonarsi

Diminished venous vascular capacitance in patients with univentricular hearts after the Fontan operation - 12/09/11

Doi : 10.1016/S0002-9149(99)80049-6 
John R. Kelley, MD a, b, Gary W. Mack, PhD , a, b, John T. Fahey, MD a, b
a From the Department of Pediatrics, Yale University School of Medicine, Yale-New Haven Hospital, USA 
b From the John B. Pierce Laboratory, New Haven, Connecticut, USA 

*Address for reprints: Gary W. Mack, PhD, John B. Pierce Laboratory, 290 Congress Avenue, New Haven, Connecticut 06519.

Abstract

Patients who have undergone Fontan's operation are known to have impaired cardiac output response to dynamic exercise. This may be due to either poor cardiac function or a limited ability to mobilize blood from capacitance vessels due to increased resting venous tone. We tested the latter hypothesis by determining venous vascular capacitance at rest and during orthostatic stress produced by lower body negative pressure (LBNP) in 6 subjects who had undergone the Fontan operation and 6 healthy age-, sex-, height-, and weight-matched controls. Resting blood volume was similar for Fontan and control subjects (79 ± 6 vs 70 ± 3 ml/kg body weight, respectively), while central venous pressure (CVP) was elevated in Fontan subjects (18.4 ± 1.0 vs 3.5 ± 0.9 mm Hg, p < 0.05). Forearm venous capacitance at a distending pressure of 40 mm Hg was less in Fontan subjects than in controls (2.6 ±0.1 vs 3.9 ± 0.5 ml/100 ml), while resting plasma norepinephrine level was elevated in Fontan subjects (255 ± 28 vs 144 ± 9 pg/ml, p < 0.05). The increase in calf volume (1.6 ± 0.2 vs 2.3 ± 0.2 ml) and decrease in CVP (−5.0 ± 0.5 vs −6.7 ± 1.1 mm Hg) during −30 mm Hg LBNP were smaller for Fontan than control subjects (p < 0.05). Reduced forearm venous capacitance and diminished pooling of blood into capacitance vessels of the leg during orthostaric stress indicated higher venous tone in Fontan than control subjects. We propose that increased resting venous tone in Fontan subjects may limit their ability to mobilize blood from capacitance vessels during exercise and may contribute to impaired cardiac output response.

Il testo completo di questo articolo è disponibile in PDF.

 This study was supported by grants HL07272, HL20634, and RR06022 from the National Institutes of Health, Bethesda, Maryland.


© 1995  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 76 - N° 3

P. 158-163 - luglio 1995 Ritorno al numero
Articolo precedente Articolo precedente
  • Coronary artery abnormalities detected at cardiac catheterization following the arterial switch operation for transposition of the great arteries
  • Ronn E. Tanel, Gil Wernovsky, Michael J. Landzberg, Stanton B. Perry, Redmond P. Burke
| Articolo seguente Articolo seguente
  • Transradial approach for coronary angiography and angioplasty
  • Chaim Lotan, Yonathan Hasin, Morris Mosseri, Yoseph Rozenman, Dan Admon, Hisham Nassar, Mervyn S. Gotsman

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.