Abbonarsi

Evaluation of Corneal Microstructure in Keratoconus: A Confocal Microscopy Study - 23/10/13

Doi : 10.1016/j.ajo.2013.05.043 
Engin Bilge Ozgurhan a, Necip Kara b, , Aydin Yildirim c, Ercument Bozkurt a, Hasim Uslu c, Ahmet Demirok a, d
a Department of Ophthalmology, Beyoglu Eye Education and Research Hospital, Istanbul, Turkey 
b Department of Ophthalmology, Sehitkamil State Hospital, Gaziantep, Turkey 
c Department of Ophthalmology, Fatih University Medical School, Sema Hospital, Istanbul, Turkey 
d Department of Ophthalmology, Istanbul Medeniyet University Medical School, Istanbul, Turkey 

Inquiries to Necip Kara, Department of Ophthalmology, Kartaltepe Mahallesi, Pancarli Mh. 58015 Sk. No. 9, Sehitkamil/Gaziantep

Abstract

Purpose

To compare the corneal microstructure in patients with manifest keratoconus (KCN), subclinical KCN, and topographically normal relatives of patients with KCN and in healthy controls.

Design

Prospective and cross-sectional study.

Methods

We enrolled 145 subjects in the study. The participants were divided into 4 groups, based on clinical and topographical evaluation: the manifest KCN group (n = 30), the subclinical KCN group (n = 32), the KCN relatives group (n = 53), and the control group (n = 30). Corneal microstructure was assessed by corneal in vivo confocal microscopy in all of the individuals. Mean outcome measures were basal epithelial cell density, endothelial cell density, anterior keratocyte density, posterior keratocyte density, sub-basal nerve density, sub-basal nerve diameter, and stromal nerve diameter.

Results

The mean basal epithelial cell density, endothelial cell density, and sub-basal nerve diameter were not significantly different among the 4 groups (P = 0.057, P = 0.592, and P = 0.393, respectively). The mean anterior and posterior stromal keratocyte densities were significantly lower in the manifest group, in the subclinical group, and in the relatives group when compared with the control group (for both parameters; P < 0.001, P < 0.001, and P< 0.001, respectively). The mean stromal nerve diameter in the manifest group, subclinical group, and relatives group was significantly higher than in the control group (P = 0.001, P = 0.049, and P = 0.004, respectively).

Conclusion

The anterior and posterior stromal keratocyte densities were statistically lower and stromal nerve diameter was statistically higher in patients with manifest KCN, subclinical KCN, and topographically normal KCN relatives compared with controls. Confocal microscopy may be useful for the determination of early corneal microstructural changes before manifestation of typical or subtle topographic signs.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2013  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 156 - N° 5

P. 885 - novembre 2013 Ritorno al numero
Articolo precedente Articolo precedente
  • Transepithelial Riboflavin/Ultraviolet. A Corneal Cross-linking in Keratoconus: Morphologic Studies on Human Corneas
  • Rita Mencucci, Iacopo Paladini, Erica Sarchielli, Eleonora Favuzza, Gabriella Barbara Vannelli, Mirca Marini
| Articolo seguente Articolo seguente
  • Anterior Segment Optical Coherence Tomography of Long-Term Phakic Angle-Supported Intraocular Lenses
  • Jorge L. Alio, Alessandro Abbouda, Pablo Peña-Garcia

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.