Abbonarsi

0315 : Atrioventricular conduction disturbance after transcatheter aortic valve implantation: incidence and predictive factors - 05/05/15

Doi : 10.1016/S1878-6480(15)30082-3 
Laurence Jesel, Audrey Lefoulon, Halim Marzak, Nathan Messas, Michel Chauvin, Olivier Morel, Patrick Ohlmann
 Nouvel Hôpital Civil, Cardiologie- Rythmologie, Strasbourg, France 

Riassunto

Purpose

Atrioventricular (AV) conduction disturbance leading to pacemaker (PM) implantation is frequent after transcatheter aortic valve implantation (TAVI). The aim of this study was to assess the incidence and the predictors of PM implantation after TAVI.

Methods

Between 2010 and 2014, 198 consecutive patients underwent TAVI in our center. 42 patients were excluded from the study because of a pre-existing PM before TAVI. 156 patients (62 Corevalve (CV), 94 Edwards Sapiens valve (ES) were included and prospectively followed during 1 year.

Results

Complete AV block occurred after TAVI in 29 patients (19%), second degree AV block in 3 (0.05%), new left bundle branch block (LBBB) in 53 (34%). A PM was implanted in 40 patients (26%). CV patients were more frequently implanted than ES (35% vs 19%; p=0.03). Post-procedure PR, QRS duration were longer in the PM group (227 vs 196ms; 159 vs 129ms, respectively, p<0.001). LBBB was also more frequent (79% vs 53%; p=0.01). At hospital discharge, 83% of the PM group was stimulated. At 1 month, 10% were PM dependent and 4% at 6 months. At 1 month, 29% were stimulated less than 5% of the time and 25% at 6 months. Multivariate analysis showed that the predictors of PM implantation were a pre-existing RBBB (OR 4.7, IC 1.43-15.52, p=0.01), a pre-existing LBBB (OR 7.28, IC 2.34-22.6, p<0.001), a per-TAVI complete AV block (OR 4.21, IC 1.52-11.63, p=0.006), a high prosthesis/annulus diameter ratio (OR 1.1, IC 1.04-1.18, p=0.003) and postprocedure PR and QRS long duration (OR 1.03, IC 1.01-1.06, p=0.009; OR 1.04, IC 1.01-1.07, p=0.009 respectively). PM implantation had no impact on survival after TAVI (Logrank=0.92). The increase in LVEF post-TAVI was lower in PM group: 0.2 vs 8%, p=0.05 at 6 months and -5 vs 9.6%, p=0.004 at 1 year. The NYHA class was similar in both groups at follow up.

Conclusion

TAVI is associated in a great proportion of patients with AV disturbances which are mostly regressive over time. Patients with pre-existing RBBB, LBBB and high prosthesis/annulus diameter ratio are at increased risk of complete AV block. LVEF increase was lower in PM group even with a low percentage of stimulation time.

Il testo completo di questo articolo è disponibile in PDF.

© 2015  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 7 - N° 2

P. 160 - aprile 2015 Ritorno al numero
Articolo precedente Articolo precedente
  • 0439 : Incidence of inappropriate ICD shocks and other complications in asymptomatic versus symptomatic Brugada syndrome
  • Aimé Bonny, Marcus Ngantcha, Abdeslam Bouzeman, Jérôme Taieb, Thibault Vaugrenard, Françoise Hidden-Lucet
| Articolo seguente Articolo seguente
  • 0344 : Pacemaker replacement in nonagenarians: procedural safety and long-term follow-up
  • Aurelie Loirat, Damien Feneon, Albin Behaghel, Nathalie Behar, Alain Le Helloco, Philippe Mabo, Jean-Claude Daubert, Christophe Leclercq, Raphaël Martins

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.