Mesure des allogreffes méniscales par microtomographies radiographiques - 06/05/15

X-ray microtomography-based measurements of meniscal allografts

Doi : 10.1016/j.rcot.2014.12.009 
P. Mickiewicz a, , M. Binkowski a, H. Bursig b, Z. Wróbel a
a X-ray microtomography lab, department of biomedical computer systems, Institute of computer science, faculty of computer and material science, university of Silesia, 75, Pułku Piechoty 1, building H, segment C, P8, 41-500, Chorzów, Pologne 
b Regional blood center, tissue bank Katowice, Raciborska 15, 40-074, Katowice, Pologne 

Auteur correspondant.

Abstract

Background

X-ray microcomputed tomography (XMT) is a technique widely used to image hard and soft tissues. Meniscal allografts as collagen structures can be imaged and analyzed using XMT. The aim of this study was to present an XMT scanning protocol that can be used to obtain the 3D geometry of menisci. It was further applied to compare two methods of meniscal allograft measurement: traditional (based on manual measurement) and novel (based on digital measurement of 3D models of menisci obtained with use of XMT scanner).

Hypothesis

The XMT-based menisci measurement is a reliable method for assessing the geometry of a meniscal allograft by measuring the basic meniscal dimensions known from traditional protocol.

Materials and methods

Thirteen dissected menisci were measured according to the same principles traditionally applied in a tissue bank. Next, the same specimens were scanned by a laboratory scanner in the XMT lab. The images were processed to obtain a 3D mesh. Three-dimensional models of allograft geometry were then measured using a novel protocol enhanced by computer software. Then, both measurements were compared using statistical tests.

Results

The results showed significant differences (P<0.05) between the lengths of the medial and lateral menisci measured in the tissue bank and the XMT Lab. Also, medial meniscal widths were significantly different (P<0.05).

Discussion

Differences in meniscal lengths may result from difficulties in dissected meniscus measurements in tissue banks, and may be related to the elastic structure of the dissected meniscus. Errors may also be caused by the lack of highlighted landmarks on the meniscal surface in this study.

Conclusion

The XMT may be a good technique for assessing meniscal dimensions without actually touching the specimen.

Level of evidence

Level IV.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Graft quality, Meniscal allograft imaging, Meniscal transplantation, X-ray microtomography



 Cet article peut être consulté in extenso dans la version anglaise de la revue Orthopaedics & Traumatology: Surgery & Research sur Science Direct (sciencedirect.com) en utilisant le DOI ci-dessus.


© 2015  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 101 - N° 3

P. 221 - maggio 2015 Ritorno al numero
Articolo precedente Articolo precedente
  • Reprise du sport après autogreffe ostéochondrale en mosaïque des condyles fémoraux : 25 cas à 9 ans de recul moyen
  • J. Cognault, O. Seurat, C. Chaussard, S. Ionescu, D. Saragaglia
| Articolo seguente Articolo seguente
  • Attentes et degré de satisfaction des patients en matière de prothèse totale de genou sur la base du questionnaire « Profex »
  • M. Kumar, P. Battepathi, P. Bangalore

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.