Automated sample hydrolysis for a forensic toxicology urine screening LC-MS/MS method - 07/05/15

Doi : 10.1016/j.toxac.2015.03.081 
A.M. Taylor 1, O.G. Cabrices 2, L.A. Lee 3, A. Wang 1, A. Morla 4,
1 Sciex, Concord, Ontario, Canada 
2 GERSTEL, USA 
3 IMCS, USA 
4 Sciex, Les Ulis, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 2
Iconografia 0
Video 0
Altro 0

Riassunto

Aim

(For research use only, not for use in diagnostic procedures). Evaluate the effectiveness of a new beta glucuronidase enzyme to efficiently hydrolyze glucuronide drugs in less than 30minutes followed by a dilute and shoot LC-MS/MS analysis.

Methods

Automated 30minute purified β-Glucuronidase (IMCS, Columbia, USA) hydrolysis was performed on spiked urine, containing 8 glucuronidated and 64 non-glucuronidated drug compounds. Samples were loaded onto a GERSTEL MPS2 equipped with an incubator that allowed for the automated hydrolysis followed by dilution and direct injection on to the LC-MS/MS system. The LC-MS/MS system consisted of an AB SCIEX QTRAP® 4500 System. LC separation was performed on a Phenomenex Kinetex 2.6μm PhenylHexyl 100Å, 50×4.6mm column at 30°C; 10minute gradient of water and methanol with ammonium formate buffer; 0.7mL/min flow rate 10μL injection volume.

Results

In order to demonstrate that the hydrolysis reaction had gone to completion within this short time period compared to the traditional 2hour hydrolysis protocol, the urine standards were analysed for the presence of the glucuronide. In all cases only the parent drug was detected and no presence of the glucuronide was observed. The reproducibility of the automated protocol was assessed by preparing and analyzing replicates of each calibration standard, and the measured CVs were less than 15% over the entire concentration range covered by the assay. The method displayed good linearity for all analytes, with R>0.99. The method was shown to be robust after monitoring response of the analytes over 900 injections. Not only does method automation eliminate human error, thus increasing reproducibility, it also eliminates subjectivity during data processing, and furthermore has the potential to save a great deal of time.

Conclusion

An automated, rapid urine hydrolysis LC-MSMS forensic toxicology screening method using the GERSTEL MPS2 as the sample preparation workstation and LC autosampler, has been investigated and has been shown to provide a viable approach to provide automated sample analysis from start to finish.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


© 2015  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 27 - N° 2S

P. S53-S54 - giugno 2015 Ritorno al numero
Articolo precedente Articolo precedente
  • High-sensitivity analysis of THC-COOH and THC in oral fluid
  • X. He, A. Wang, A.M. Taylor, A. Morla
| Articolo seguente Articolo seguente
  • Dosage simultané de 15 produits stupéfiants dans les cheveux par LC-MS/MS avec extraction en ligne
  • H. Grison-Hernando, C. Renaud, G. Deslandes, A. Pineau, E. Dailly, R. Bouquie, C. Azoulay-Fauconnier, P. Jolliet, C. Monteil-Ganiere

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.