Change in acetabular version after lumbar pedicle subtraction osteotomy to correct post-operative flat back: EOS® measurements of 38 acetabula - 06/10/15

Doi : 10.1016/j.otsr.2015.07.013 
T. Masquefa , N. Verdier, O. Gille, L. Boissière, I. Obeid, C. Maillot, C. Tournier, T. Fabre
 Service d’orthopédie traumatologie, hôpital Pellegrin, place Amélie-Raba-Leon, 33076 Bordeaux cedex, France 

Corresponding author. Tel.: +33 6 75 01 54 02.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Abnormalities in acetabular orientation can promote the development of hip osteoarthritis, femoro-acetabular impingement, or even acetabular cup malposition. The objective of the present study was to determine whether pedicle substraction osteotomy (PSO) to correct sagittal spinal imbalance affected acetabular orientation.

Hypothesis

PSO performed to correct sagittal spinal imbalance affects acetabular orientation by changing the pelvic parameters.

Materials and methods

This was a descriptive study in which two observers measured the acetabular parameters on both sides in 19 patients (38 acetabula) before and after PSO for post-operative flat-back syndrome. Mean time from PSO to post-operative measurements was 19months. Measurements were taken twice at a 2-week interval, on standing images obtained using the EOS® imaging system and sterEOS® software to obtain 3D reconstructions of synchronised 2D images. Acetabular anteversion and inclination were measured relative to the vertical plane. Mean pre-PSO and post-PSO values were compared using the paired t-test, and P values lower than 0.05 were considered significant. To assess inter-observer and intra-observer reproducibility, we computed the intra-class correlation coefficients (ICCs).

Results

The measurements showed significant acetabular retroversion after PSO, of 7.6° on the right and 6.5° on the left (P<0.001). Acetabular inclination diminished significantly, by 4.5° on the right and 2.5° on the left (P<0.01). Inclination of the anterior pelvic plane decreased by 8.4° (P<0.01). Pelvic incidence was unchanged, whereas sacral slope increased by 10.5° (P<0.001) and pelvic tilt decreased by 10.9° (P<0.001). The ICC was 0.98 for both inter-observer and intra-observer reproducibility.

Conclusion

Changing the sagittal spinal alignment modifies both the pelvic and the acetabular parameters. PSO significantly increases sacral slope, thus inducing anterior pelvic tilt with significant acetabular retroversion. The measurements obtained using sterEOS® showed good inter-observer and intra-observer reproducibility. To our knowledge, this is the first study of changes in acetabular version after PSO.

Le texte complet de cet article est disponible en PDF.

Keywords : Acetabular retroversion, Transpedicular osteotomy, Pedicle subtraction osteotomy, Total hip arthroplasty, Sagittal balance


Plan


© 2015  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 101 - N° 6

P. 655-659 - octobre 2015 Retour au numéro
Article précédent Article précédent
  • Comparison of the reliability of leg length and offset data generated by three hip replacement CAOS systems using EOS™ imaging
  • A. Clavé, F. Fazilleau, D. Cheval, T. Williams, C. Lefèvre, E. Stindel
| Article suivant Article suivant
  • Excellent short-term results of hip resurfacing in a selected population of young patients
  • A. Lons, A. Arnould, T. Pommepuy, E. Drumez, J. Girard

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.