S'abonner

Prospective study of a non-restrictive decision rule for acute aortic syndrome - 21/08/17

Doi : 10.1016/j.ajem.2017.04.014 
Judah Goldschmiedt, MD a, 1, Jeffrey M. Levsky, MD PhD a, b, Eran Y. Bellin, MD MPH b, c, Esther Mizrachi, MD a, d, 2, David Esses, MD d, Linda B. Haramati, MD, MS a, b,
a Department of Radiology, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, NY 10467, United States 
b Department of Medicine, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, NY 10467, United States 
c Department of Epidemiology, Population Health, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, NY 10467, United States 
d Department of Emergency Medicine, Montefiore Medical Center and Albert Einstein College of Medicine, Bronx, NY 10467, United States 

Corresponding author at: Department of Radiology, Montefiore Medical Center, 111 East 210 Street, Bronx, NY, United States.Department of RadiologyMontefiore Medical Center111 East 210 StreetBronxNYUnited States

Abstract

Objectives

To determine the impact of a non-restrictive clinical decision rule on CT utilization for Emergency Department patients suspected of having an acute aortic syndrome (AAS).

Methods

We prospectively assessed the performance of a previously described, collaboratively designed, non-restrictive clinical decision rule for AAS. Emergency Department patients with suspected AAS were stratified into low and high-risk groups based on decision rule results, from July 2013–August 2014. Patients with acute trauma, prior AAS or aortic surgery were excluded. CT dose reduction protocols were concurrently implemented as a quality improvement measure. Bivariate analysis was performed to compare the prospective cohort with the historical derivation cohort for CT utilization rates, results of CT, AAS incidence and radiation exposure. The performance of the clinical decision rule was evaluated.

Results

Compared with the historic cohort, the study cohort demonstrated a lower CT utilization rate [0.344% (427/124,093) versus 0.477% (1465/306,961), (p<0.001)], a trend toward higher CT diagnostic yield [4.4% (19/427) versus 2.7% (40/1465), (p=0.08)]. AAS incidence was similar [0.015% (19/124,093) versus 0.013% (40/306,961), (p=0.57)]. The mean effective radiation dose was markedly lower [12±5.5mSv versus 43±20mSv, (p<0.0001)]. The clinical decision rule correctly stratified only 56% (10/18) of patients with AAS as high-risk.

Conclusions

A non-restrictive, collaboratively designed, clinical decision rule for Emergency Department patients with suspected AAS performed poorly in risk-stratifying patients for AAS. However, its implementation was associated with a significant and safe decrease in CT utilization.

Le texte complet de cet article est disponible en PDF.

Keywords : Computed tomography, Aorta dissection, Aorta rupture, Radiation exposure


Plan


© 2017  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 35 - N° 9

P. 1309-1313 - septembre 2017 Retour au numéro
Article précédent Article précédent
  • Effectiveness of finger-marker for maintaining the correct compression point during paediatric resuscitation: A simulation study
  • Jae Yun Jung, Young Ho Kwak, Hyuksool Kwon, Yoo Jin Choi, Do Kyun Kim, Hee Chan Kim, Jung Chan Lee, Ji Heum Park, Hyungsoo Lim
| Article suivant Article suivant
  • Incidence and clinical features of sacral insufficiency fracture in the emergency department
  • Yasuaki Tamaki, Akihiro Nagamachi, Kazumasa Inoue, Makoto Takeuchi, Kosuke Sugiura, Yasuyuki Omichi, Shunsuke Tamaki, Takashi Chikawa, Koichi Sairyo, Keisuke Adachi

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.