S'abonner

A pilot single-center prospective randomized trial to assess the short-term effect of a flashing warning light on reducing fluoroscopy time and radiation exposure during ERCP - 16/07/18

Doi : 10.1016/j.gie.2018.03.008 
Hong-Ze Zeng, MD, Qin Liu, MMed, Hong-Lin Chen, MMed, Wei Liu, MD, Qi-Shan Zeng, MMed, Chun-Cheng Wu, MMed, Bing Hu, MD
 Department of Gastroenterology, West China Hospital, Sichuan University, Chengdu, Sichuan, China 

Reprint requests: Bing Hu, MD, Department of Gastroenterology, West China Hospital, Sichuan University, No. 37 Guo Xue Xiang, Chengdu, Sichuan, 610041, China.Department of GastroenterologyWest China HospitalSichuan UniversityNo. 37 Guo Xue XiangChengduSichuan610041China

Abstract

Background and Aims

ERCP has the risk of exposure to ionizing radiation. Performers may unconsciously increase fluoroscopy time (FT) because of a lack of radiation protection awareness. This study investigates whether a flashing warning light adopted as a behavioral intervention for performers reduces FT and radiation exposure during ERCP.

Methods

We conducted a prospective randomized trial of 200 therapeutic ERCPs. A flashing warning light was placed on top of the endoscopy monitor. Cases were consecutively enrolled and randomly assigned to 2 groups in a 1:1 ratio. In the warning light group, the light was on when the fluoroscopy foot pedal was depressed; in the control group, the light was off. Fluoroscopy and procedure-related data were recorded.

Results

The median FT and dose-area product (DAP) for the warning light group versus the control group were 142.5 seconds versus 175.0 seconds (P = .045) and 856.8 μGy∙m2 versus 1054.4 μGy∙m2 (P = .043). In a multivariable analysis, the use of the warning light was found to reduce FT by 15.4% (–27.0 seconds; P = .042). DAP reduction because of the decreased FT was 15.2% (160.3 μGy∙m2). The reduction in patient effective dose per case was .42 mSv, equivalent to 21 chest radiographs. No adverse events or interference with the procedures because of the warning light were noted.

Conclusions

The use of a flashing warning light is a feasible way to reduce FT and radiation exposure during ERCP. (Clinical trial registration number: ChiCTR-IPR-14005349.)

Le texte complet de cet article est disponible en PDF.

Abbreviations : DAP, FT


Plan


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication.


© 2018  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 88 - N° 2

P. 261-266 - août 2018 Retour au numéro
Article précédent Article précédent
  • Water-pocket endoscopic submucosal dissection for superficial gastric neoplasms (with video)
  • Hideaki Harada, Daisuke Murakami, Satoshi Suehiro, Ryotaro Nakahara, Tetsuro Ujihara, Ryota Sagami, Yasushi Katsuyama, Kenji Hayasaka, Yuji Amano
| Article suivant Article suivant
  • Cost-effectiveness analysis comparing lumen-apposing metal stents with plastic stents in the management of pancreatic walled-off necrosis
  • Yen-I Chen, Alan N. Barkun, Viviane Adam, Ge Bai, Vikesh K. Singh, Majidah Bukhari, Olaya Brewer Gutierrez, B. Joseph Elmunzer, Robert Moran, Lea Fayad, Mohamad El Zein, Vivek Kumbhari, Alessandro Repici, Mouen A. Khashab

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.