S'abonner

A novel submucosal injection solution for endoscopic resection of large colorectal lesions: a randomized, double-blind trial - 15/08/18

Doi : 10.1016/j.gie.2018.04.2363 
Alessandro Repici, MD 1, , Michael Wallace, MD, MPH 2, Prateek Sharma, MD 3, Pradeep Bhandari, MD, PhD 4, Gianluca Lollo, MD 1, Roberta Maselli, MD 1, Cesare Hassan, MD 5, Douglas K. Rex, MD 6
1 Humanitas Research Hospital, Humanitas University, Milan, Italy 
2 Department of Gastroenterology and Hepatology Mayo Clinic Florida, Jacksonville, Florida, USA 
3 University of Kansas Medical Center, Kansas City, Kansas, USA 
4 Solent Centre for Digestive Diseases, Portsmouth, United Kingdom 
5 Endoscopy Unit, Nuovo Regina Margherita Hospital, Rome, Italy 
6 Indiana University Medical Center, Indianapolis, Indiana, USA 

Reprint requests: Prof. Alessandro Repici, Digestive Endoscopy Unit Humanitas Research Hospital, Humanitas University, Via Manzoni 5620089 Rozzano (Milan) Italy.Digestive Endoscopy Unit Humanitas Research HospitalHumanitas UniversityVia ManzoniRozzano (Milan)5620089Italy

Abstract

Background and Aims

SIC-8000 (Eleview) is a new U.S. Food and Drug Administration (FDA)-approved solution for submucosal injection developed to provide a long-lasting cushion to facilitate endoscopic resection maneuvers. Our aim was to compare the efficacy and safety of SIC-8000 with those of saline solution, when performing EMR of large colorectal lesions.

Methods

In a randomized double-blind trial, patients undergoing EMR for colorectal non-pedunculated lesions ≥20 mm were randomized in a 1:1 ratio between SIC-8000 and saline solution as control solution in 5 tertiary centers. Endoscopists and patients were blinded to the type of submucosal solution used. Total volume to complete EMR and per lesion size and time of resection were primary endpoints; the Sydney Resection Quotient (SRQ), as well as other EMR outcomes, and the rate of adverse events were secondary endpoints. A 30-day telephone follow-up was performed. An alpha level <0.05 was considered as statistically significant.

Results

Of the 327 patients screened, 226 (mean age, 66 ± 10 years; males, 56%) were enrolled in the study and randomized between the 2 submucosal agents. Of these, 211 patients (mean size of the lesions 33 ± 13 mm; Paris class Is, 36%; proximal colon, 74%) were entered in the final analysis (SIC-8000, 102; saline solution, 109). EMR was complete in all cases. The total volume needed for EMR was significantly less in the SIC-8000 arm compared with saline group (16.1 ± 9.8 mL vs 31.6 ± 32.0 mL; P < .001). This corresponded to an average volume per lesion size of 0.5 ± 0.3 mL/mm and 0.9 ± 0.6 mL/mm with SIC-8000 and saline solution, respectively (P < .001). The mean time to completely resect the lesion tended to be lower with SIC-8000 than with saline solution (19.1 ± 16.8 minutes vs 29.7 ± 68.9 minutes; P = .1). The SRQ was significantly higher with SIC-8000 compared with saline solution (10.3 ± 8.1 vs 8.0 ± 5.7; P = .04) with a trend for a lower number of resected pieces (5.7 ± 6.0 vs 6.5 ± 5.04; P = .052) and a higher rate of en bloc resections (19/102, 18.6% vs 12/111, 11.0%; P = .1). The rate of adverse events was similar between the 2 arms (SIC-8000, 18.6%; saline solution, 17%), and none of the serious adverse events (SIC-8000, 8.8%; saline solution, 10.7%) were related to the study treatment.

Conclusions

In a double-blind, randomized clinical trial, a new FDA-approved agent for sub-mucosal injection appeared to be a more effective and equally safe submucosal agent for EMR injection than saline solution. (Clinical trial registration number: NCT02654418.)

Le texte complet de cet article est disponible en PDF.

Abbreviations : ITT, PP, SRQ, SS


Plan


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication.
 See CME section; p. 542.
 If you would like to chat with an author of this article, you may contact Professor Repici at alessandro.repici@hunimed.eu.


© 2018  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 88 - N° 3

P. 527 - septembre 2018 Retour au numéro
Article précédent Article précédent
  • Immunohistologic analysis of the duodenal bulb: a new method for celiac disease diagnosis in children
  • Luigina De Leo, Vincenzo Villanacci, Fabiana Ziberna, Serena Vatta, Stefano Martelossi, Grazia Di Leo, Chiara Zanchi, Matteo Bramuzzo, Fabiola Giudici, Alessandro Ventura, Tarcisio Not
| Article suivant Article suivant
  • Alternative approaches to polyp extraction in colonoscopy: a proof of principle study
  • William Barge, Deepak Kumar, Deborah Giusto, Jason Kramer, Rama Behara, Shriram Jakate, Faraz Bishehsari, John Losurdo, Salina Lee, Shubha Singh, Joshua Melson

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.