Quality validation of platelets obtained from the Haemonetics and Trima Accel automated blood-collection systems - 20/11/20

Doi : 10.1016/j.tracli.2020.10.010 
Hsuan-Hui Wang 1, 2, Li-Na Liao 3, Chi-Ling Lin 2, Ling-Ling Yen 2, Yi-Min Hsiao 5, , Jiunn-Liang Ko 1, 4,
1 Institute of Medicine, Chung Shan Medical University, Taichung, Taiwan 
2 Taichung Blood Center, Taiwan Blood Services Foundation, Taichung, Taiwan 
3 Department of Public Health, College of Public Health, China Medical University, Taichung, Taiwan 
4 Department of Medical Oncology and Chest Medicine, Chung Shan Medical University Hospital, Taiwan 
5 Department of Medical Laboratory Science and Biotechnology, Central Taiwan University of Science and Technology, Taichung, Taiwan 

Corresponding authors: Institute of Medicine, Chung Shan Medical University, 110, Sec. 1, Chien-Kuo N. Road, 40203 Taichung, TaiwanInstitute of Medicine, Chung Shan Medical University110, Sec. 1, Chien-Kuo N. RoadTaichung40203Taiwan⁎⁎Corresponding authors: Department of Medical Laboratory Science and Biotechnology, Central Taiwan University of Science and Technology, Taichung, TaiwanDepartment of Medical Laboratory Science and Biotechnology, Central Taiwan University of Science and TechnologyTaichungTaiwan
Sous presse. Manuscrit accepté. Disponible en ligne depuis le Friday 20 November 2020
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background: Platelet transfusion is required to treat haemo-oncology or trauma patients. Platelet apheresis (PPH) performed with apheresis equipment has increased rapidly in recent years. Leucocyte-reduced platelet apheresis (LRPH) can reduce the risk of platelet refractoriness and febrile nonhemolytic transfusion reactions (FNHTRs) for transfusion. Accordingly, this study aimed to investigate and compare the platelet metabolic and functional responses between PPH performed with Haemonetics and LRPH performed with Trima Accel cell separator.

Methods: The qualities of platelets collected through PPH and LRPH were evaluated in terms of visual appearance, morphology, platelet-aggregation changes, metabolic activities, and bacterium-screening test during 5-day storage. Statistical analyses included two-sample t-test and generalised estimating equation(GEE) method.

Results: During 5-day storage in LRPH, residual leucocytes were all <1.0×106, and the parameters of platelet function were as follows: platelet aggregated to agonists such as adenosine 5′-diphosphate (ADP) and collagen, and the extent of shape change and pO2 showed no statistically significant difference between PPH and LRPH. The hypotonic shock reaction (HSR) on days 0, 1, and 3 were significantly higher in LRPH than in PPH (71.78±6.92 vs. 64.10±7.42; p=0.002; 71.53±8.98 vs. 62.96±9.84; p=0.007; 68.05±7.28 vs. 57.76±6.80; p<0.0001, respectively). Values of mean platelet volume (MPV) were statistically larger in PPH than in LRPH on days 0, 1, and 3. On day 5, the swirling score was higher in LRPH than in PPH. The mean lactate levels had no statistically significant difference between PPH and LRPH. Moreover, no growth was observed through bacterium-screening test conducted on 40 samples.

Conclusion: Comparison of LRPH and PPH products collected from the Trima Accel and Haemonetics automated blood-collection systems, respectively, revealed that both products possessed good platelet qualities even though additional processes are needed to reduce leucocytes. Furthermore, investigating the outcomes of other apheresis instruments with focus on the safety of donors, products, and recipients is necessary.

Le texte complet de cet article est disponible en PDF.

Keywords : platelet apheresis (PPH), leucocyte-reduced platelets apheresis (LRPH), platelet qualities, bacterium-screening test



© 2020  Société française de transfusion sanguine (SFTS). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.