Utilizing 3D Printing and Hydrogel Casting for the Development of Patient-Specific Rehearsal Platforms for Robotic Assisted Partial Nephrectomies - 31/12/20

Doi : 10.1016/j.urology.2020.10.023 
Ahmed Ghazi , Patrick Saba, Rachel Melnyk, Jean Joseph
 University of Rochester Medical Center, Division Department of Urology, 601 Elmwood Ave, Rochester, NY 

Address correspondence to: Ahmed Ghazi, M.D., University of Rochester Medical Center, Division Department of Urology, 601 Elmwood Ave, Rochester, NY 14642University of Rochester Medical CenterDivision Department of Urology601 Elmwood AveRochesterNY14642

Résumé

BACKGROUND

Three-dimensional (3D) printing technology has been utilized to create patient-specific (PS) replicas as visual aids for surgical planning.1, 2, 3, 4 However, they cannot recreate the operative experience due to a lack of realistic tissue characteristics.

OBJECTIVES

Develop anatomically accurate, realistic, PS partial nephrectomy platforms suitable for pre-operative surgical rehearsals using 3D-printing and hydrogel casting.

MATERIAL

Patient CT scans were segmented into a computer-aided design (CAD) file and used to create injection casts. Kidney and tumor casts along with hollow vascular and urinary structures were 3D-printed. The hilar structures and tumor were registered into the kidney cast, injected with poly-vinyl alcohol (PVA) hydrogel, and processed to create the kidney phantom. Mechanical and functional testing protocols were completed to confirm that the properties of PVA matched the live tissue.5 Anatomical accuracy was confirmed by CT scanning the phantom and creating another CAD, which was compared to the original patient CAD. Full-procedural PS rehearsals were completed 24-48 hours prior to their respective live surgeries. Clinically relevant metrics (warm ischemia time, estimated blood loss, and positive surgical margins) from each rehearsal and live case were compared using a Wilcoxon-rank sum test.

RESULTS

The 7%-3freeze/thaw PVA best recreated the mechanical and functional properties of porcine kidneys, while anatomical verification showed ≤1 mm deviation of the kidney and tumor from the patient anatomy and ≤3 mm for the hilar structures. PS rehearsal platforms were fabricated using these methods for 8 patients (average tumor size 5.92 cm and nephrometry score 9.8). A positive correlation was found for warm ischemia time and estimated blood loss between rehearsals and live surgeries.

CONCLUSION

This reproducible method shows high anatomical accuracy, realistic tissue properties, and translational effects between rehearsals and live surgery. To determine the effects on patient outcomes, future studies will compare the impact of completing a pre-operative rehearsal vs standard surgical preparation.

Le texte complet de cet article est disponible en PDF.

 Author Disclosure: Dr. Ahmed Ghazi – Consultant for Olympus and Johnson & Johnson, Research Grant from Intuitive (All unrelated to this project)
 All other authors have no conflicts of interest.


© 2020  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 147

P. 317 - janvier 2021 Retour au numéro
Article précédent Article précédent
  • Robot-Assisted Laparoscopic Bladder Diverticulectomy: Adaptation of Techniques for a Variety of Clinical Presentations
  • Shuo Liu, Ram A Pathak, Ashok K Hemal
| Article suivant Article suivant
  • A Modified Neobladder Technique: The “I-Pouch” – Illustration of Surgical Approach and Tricks
  • Juan Samuel Izquierdo-Luna, Valentina Norz, Jens Bedke, Stefan Aufderklamm, Bastian Amend, Johannes Mischinger, Georgios Gakis, Arnulf Stenzl, Steffen Rausch

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.