S'abonner

Guidance for setting easy-to-adopt competence criteria for optical diagnosis of diminutive colorectal polyps: a simulation approach - 14/09/21

Doi : 10.1016/j.gie.2021.04.008 
Britt B.S. L. Houwen, MD 1, Marjolein J.E. Greuter, MSc, PhD 2, Jasper L.A. Vleugels, MD, PhD 1, Yark Hazewinkel, MD, PhD 3, Raf Bisschops, MD, PhD 4, Evelien Dekker, MD, PhD 1, , Veerle M.H. Coupé, MSc, PhD 2
1 Department of Gastroenterology and Hepatology, Amsterdam University Medical Centers, location Academic Medical Center, University of Amsterdam, Amsterdam, the Netherlands 
2 Department of Epidemiology and Data Science, Amsterdam University Medical Centers, location VU Medical Center, VU University of Amsterdam, Amsterdam, the Netherlands 
3 Department of Gastroenterology and Hepatology, Radboud University Nijmegen Medical Center, Radboud University of Nijmegen, Nijmegen, the Netherlands 
4 Department of Gastroenterology and Hepatology, University Hospital Leuven, Leuven, Belgium 

Reprint requests: Evelien Dekker, MD, PhD, Amsterdam University Medical Centers, location Academic Medical Center, Department of Gastroenterology and Hepatology, Meibergdreef 9, 1105 AZ Amsterdam, The Netherlands.Amsterdam University Medical Centerslocation Academic Medical CenterDepartment of Gastroenterology and HepatologyMeibergdreef 9Amsterdam1105 AZThe Netherlands

Abstract

Background and Aims

One reason the optical diagnosis strategy for diminutive colorectal polyps has not yet been implemented is that the current competence criteria (Preservation and Incorporation of Valuable Endoscopic Innovation [PIVI] initiative) are difficult to use in daily practice. To provide guidance for setting alternative easy-to-adopt competence criteria, we determined the lowest proportion of diminutive polyps that should have a correct optical diagnosis to meet the PIVI.

Methods

For this simulation study, we used datasets from 2 prospectively collected cohorts of patients who underwent colonoscopy in either a primary colonoscopy or fecal immunochemical test (FIT) screening setting. In the simulation approach, virtual endoscopists or computer-aided diagnosis systems performed optical diagnosis of diminutive polyps with a fixed diagnostic performance level (strategy) on all individuals in the cohort who had ≥1 diminutive polyp. Strategies were defined by systematically varying the proportion of correct optical diagnoses for each polyp subtype (ie, adenomas, hyperplastic polyps, sessile serrated lesions). For each strategy, we determined whether PIVI-1 (≥90% agreement with U.S. or European Society for Gastrointestinal Endoscopy [ESGE] surveillance guidelines) and PIVI-2 (≥90% negative predictive value [NPV] for neoplastic lesions in the rectosigmoid) were met using Monte Carlo sampling with 1000 repetitions, with histology as reference.

Results

The level of overall diagnostic accuracy to achieve the PIVI differed significantly depending on the clinical setting and guidelines used. In the colonoscopy screening setting, all diagnostic strategies in which 92% of all diminutive polyps (regardless of histology) were diagnosed correctly led to 90% or more agreement with U.S. surveillance intervals (ie, PIVI-1). For all diagnostic strategies in which ≥89% of all diminutive polyps were correctly diagnosed, at least 90% NPV was achieved (ie, PIVI-2). For the FIT screening setting, values were respectively ≥77% and ≥94%. When using ESGE guidelines, PIVI-1 was in both settings already met when 40% of all diminutive polyps were diagnosed correctly.

Conclusions

In contrast to the fixed PIVI criteria, our simulation study shows that different thresholds for the proportion of correctly diagnosed diminutive polyps lead to different clinical consequences depending on guidelines and clinical setting. However, this target proportion of diminutive colorectal polyps correctly diagnosed with optical diagnosis represents easier-to-adopt competence criteria.

Le texte complet de cet article est disponible en PDF.

Abbreviations : CADx, ESGE, FIT, HP, NPV, PIVI, SSL


Plan


 DISCLOSURE: The following authors disclosed financial relationships: R. Bisschops: Consultant for Pentax, Fujifilm, GI Supply, Norgine, Ipsen, Medtronic, and Cook; research grants from Pentax and Fujifilm; speaker for Pentax and Fujifilm. E. Dekker: Equipment on loan from Olympus and Fujifilm; research grant from Fujifilm; consultant for Tillots, Fujifilm, GI Supply, CPP-FAP, and PAION; speaker for Roche, Norgine, and GI Supply. All other authors disclosed no financial relationships.


© 2021  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 94 - N° 4

P. 812 - octobre 2021 Retour au numéro
Article précédent Article précédent
  • Endoscopic characteristics influencing postpolypectomy bleeding in 1147 consecutive pedunculated colonic polyps: a multicenter retrospective study
  • Teppei Tagawa, Masayoshi Yamada, Takeyoshi Minagawa, Masanori Sekiguchi, Kenichi Konda, Hirohito Tanaka, Hiroyuki Takamaru, Masau Sekiguchi, Taku Sakamoto, Takahisa Matsuda, Aya Kuchiba, Hitoshi Yoshida, Yutaka Saito
| Article suivant Article suivant
  • Novel 1-L polyethylene glycol + ascorbate versus high-volume polyethylene glycol regimen for colonoscopy cleansing: a multicenter, randomized, phase IV study
  • Alessandro Repici, Cristiano Spada, Renato Cannizzaro, Mario Traina, Roberta Maselli, Stefania Maiero, Alessia Galtieri, Giovanni Guarnieri, Milena Di Leo, Roberto Lorenzetti, Antonio Capogreco, Marco Spadaccini, Giulio Antonelli, Angelo Zullo, Michele Amata, Elisa Ferrara, Loredana Correale, Antonino Granata, Paola Cesaro, Franco Radaelli, Leonardo Minelli Grazioli, Andrea Anderloni, Alessandro Fugazza, Elena Finati, Gaia Pellegatta, Silvia Carrara, Pietro Occhipinti, Andrea Buda, Lorenzo Fuccio, Mauro Manno, Cesare Hassan

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.