S'abonner

Multi-library synchronization for suspect screening using LC-HRMS: The importance of InChIkeys - 15/08/22

Doi : 10.1016/j.toxac.2022.06.165 
Petur W. Dalsgaard , Christian B. Mollerup, Daniel Pasin
 University of copenhagen, Section of forensic chemistry, Copenhagen, Denmark 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Résumé

Aim

To generate two major LC-HRMS semi-targeted screening libraries in addition to the in-house targeted library: (1) an extended general toxicology library by synchronizing an in-house targeted library with compounds found in Baselt's 12th Edition of Disposition of Toxic Drugs and Chemicals in Man, and (2) the extended general toxicology library synchronized with HighResNPS, a comprehensive database of NPS.

Method

Firstly, InChiKeys for the compounds (n=1765) in the Waters Forensic Toxicology Screening Library (i.e. the targeted Library) were extracted in addition to the observed retention times and product ions. Secondly, compounds listed in Baselt (n=2057) were extracted from the contents and then converted to simplified molecular-input line-entry system (SMILES) strings and InChIKeys using Python's cheminformatics package, rdkit. Compounds which were not suited for LC-ESI-MS analysis, such as volatiles and elements, and compounds with masses either less than 50Da or greater than 1,000Da were removed. The precursor ion masses of the remaining compounds were calculated from the SMILES string. Lastly, the January 2022 library was downloaded from HighResNPS (n=2166), which contained InChIKeys and, both observed (n=351) and predicted (n=1815) retention times. Using the connectivity layer of the InChIKey, i.e. the first 14 characters, the target library and the Baselt library were combined so that only the unique compounds from each library were included to create the Baselt semi-target library. Similarly, the Baselt semi-target library was then combined with the HighResNPS library to create the HighResNPS semi-target library. These libraries were then converted to a Waters Corporation UNIFI library format (.ulc) and applied to special cases submitted in 2021–2022.

Results

The Baselt semi-target library consisted of 2690 compounds of which 925 were unique to the Baselt library while the HighResNPS semi-targeted library consisted of 4242 compounds of which, 1552 were unique to the HighResNPS library. The application of the Baselt semi-target library to selected special cases resulted in the detection of compounds like vortioxetine, darunavir, abacavir, zonisamide, drotaverine and brexpiprazole were detected in blood. Similarly, 3-Me-PCPy and 5F-3,5-AB-PFUPPYCA were detected in seized material using the HighResNPS semi-target library.

The use of only the in-house targeted libraries would have missed these relevant compounds in both forensic toxicology and forensic chemistry contexts. The use of InChIKeys rather than compound names or other standard identifiers made it easy to identify the unique compounds in each of the selected libraries with little effort and thus increased the scope by 52% and 140% relative to the target library.

Conclusion

Inclusion of InChIKeys in target libraries offers the possibility for laboratories to synchronize their libraries with libraries from other laboratories to broaden their screening capacity.

Le texte complet de cet article est disponible en PDF.

Plan


© 2022  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 34 - N° 3S

P. S105 - septembre 2022 Retour au numéro
Article précédent Article précédent
  • The systematic investigation of the role of adulterants into the postmortem redistribution of heroin
  • Nebile Daglioglu, Ismail Ethem Gören, Yusuf Kenan Daglioglu, Asli Atasoy, Pinar Efeoglu Ozseker
| Article suivant Article suivant
  • Quantification of phosphatidylethanol combining dried blood spots sampling with Orbitrap-based LC-HRMS platform: Method validation and proficiency testing
  • Julien Déglon, Timothée Joye, Estelle Lauer, Aurélien Thomas, Marc Augsburger

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.