A Pilot Study: Detrusor Overactivity Diagnosis Method Based on Deep Learning - 03/10/23

Doi : 10.1016/j.urology.2023.04.030 
Quan Zhou a, 1, Zhong Chen b, c, Bo Wu a, Dongxu Lin b, Youmin Hu a, , Xin Zhang a, Jie Liu d
a School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan, China 
b Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China 
c Department of Urology, Tongji Hospital of Tongji Medical College of Huazhong University of Science and Technology, Wuhan, China 
d School of Civil and Hydraulic Engineering, Huazhong University of Science and Technology, Wuhan, China 

Address correspondence to: Youmin Hu, PhD, School of Mechanical Science and Engineering, Huazhong University of Science and Technology, Wuhan 430074, China.School of Mechanical Science and Engineering, Huazhong University of Science and TechnologyWuhan430074China

Résumé

Objective

To develop two intelligent diagnosis models of detrusor overactivity (DO) based on deep learning to assist doctors no longer heavily rely on visual observation of urodynamic study (UDS) curves.

Methods

UDS curves of 92 patients were collected during 2019. We constructed two DO event recognition models based on convolutional neural network (CNN) with 44 samples, and tested the model performance with the remaining 48 samples by comparing other four classical machine learning models. During the testing phase, we developed a threshold screening strategy to quickly filter out suspected DO event segments in each patient's UDS curve. If two or more DO event fragments are determined to be DO by the diagnostic model, the patient is diagnosed as having DO.

Results

We extracted 146 DO event samples and 1863 non-DO event samples from the UDS curves of 44 patients to train CNN models. Through 10-fold cross-validation, the training accuracy and validation accuracy of our models achieved the highest accuracy. In the model testing phase, we used a threshold screening strategy to quickly screen out the suspected DO event samples in the UDS curve of another 48 patients, and then input them into the trained models. Finally, the diagnostic accuracy of patients without DO and patients with DO was 78.12% and 100%, respectively.

Conclusion

Under the available data, the accuracy of the DO diagnostic model based on CNN is satisfactory. With the increase of the amount of data, the deep learning model is likely to have better performance.

Clinical trial registration

This experiment was certified by the Chinese Clinical Trial Registry (ChiCTR2200063467).

Le texte complet de cet article est disponible en PDF.

Plan


 Funding Support: Supported by the scientific and technological project in Hubei Province, China (2020BAB028).


© 2023  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 179

P. 188-195 - septembre 2023 Retour au numéro
Article précédent Article précédent
  • Shattered Kidney After Renal Trauma: Should It Be Classified As an American Association for the Surgery of Trauma Grade V Injury?
  • Sorena Keihani, Douglas M. Rogers, Sherry S. Wang, Joel A. Gross, Ryan P. Joyce, Judith C. Hagedorn, Sarah Majercik, Rachel L. Sensenig, Ian Schwartz, Bradley A. Erickson, Rachel A. Moses, J. Patrick Selph, Scott Norwood, Brian P. Smith, Christopher M. Dodgion, Kaushik Mukherjee, Benjamin N. Breyer, Nima Baradaran, Jeremy B. Myers, (primary investigator), for the Multi-institutional Genito-Urinary Trauma Study Group (MiGUTS)
| Article suivant Article suivant
  • AUTHOR REPLY
  • Quan Zhou, Zhong Chen, Youmin Hu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.