S'abonner

Comparing CBCT to model scanner for dental model scanning. An in vitro imaging accuracy study - 12/01/24

Doi : 10.1016/j.ortho.2023.100840 
Ioannis A. Tsolakis 1, 2, , Aliki Rontogianni 3, Apostolos I. Tsolakis 2, 3, Moschos A. Papadopoulos 1
1 Department of Orthodontics, School of Dentistry, Faculty of Health Sciences, Aristotle University of Thessaloniki, Thessaloniki, Greece 
2 Department of Orthodontics, School of Dental Medicine, Case Western Reserve University, Cleveland, OH, USA 
3 Department of Orthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece 

Ioannis A. Tsolakis, Dentistry Building, Aristotle University of Thessaloniki Campus, Thessaloniki 54124, Greece.Dentistry Building, Aristotle University of Thessaloniki CampusThessaloniki54124Greece

Summary

Objective

The aim of this study is to compare the accuracy of cone beam computed tomography (CBCT) for dental model scanning to the accuracy of model scanners.

Methods

Subjects from private practice were collected and scanned according to specific selection criteria. A total of 10 STL files were produced and used as reference files. They were printed with a three-dimensional (3D) printer and then scanned with CBCT and model scanner. For trueness evaluation, all models were scanned once with both equipments. Each file derived from each scan was compared with the corresponding reference model file. For the precision measurements, the physical model from the first master reference model file was scanned 10 times with each equipment and compared with the reference STL file. A reverse engineering software was used for all 3D best-fit comparisons.

Results

With regard to the measurement of trueness of each method, the calculated mean root mean square (RMS) value was 0.06±0.01mm for the CBCT, and 0.15±0.02mm for the model scanner. There was a significant difference between the two methods (P<0.01). For the evaluation of precision of each scanner, the mean RMS value was 0.0056±0.001mm for the CBCT, and 0.153±0.002mm for model scanner. There was a significant difference between the two methods (P<0.01).

Conclusions

Cone Beam Computed Tomography seems to be an accurate method for scanning dental models. CBCT performs better than model scanners to scan dental models in terms of trueness and precision.

Le texte complet de cet article est disponible en PDF.

Keywords : CBCT, Model scanner, Accuracy


Plan


© 2023  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 22 - N° 1

Article 100840- mars 2024 Retour au numéro
Article précédent Article précédent
  • Three-dimensional analysis of posterior tooth inclinations in transverse and sagittal relationships: A cross-sectional study
  • Guto de Oliveira e Silva, Thiago Santos Mendes, Diego Patrik Alves Carneiro, Carolina Carmo de Menezes, Silvia Amélia Scudeler Vedovello, Ana Paula Terossi de Godoi
| Article suivant Article suivant
  • Shear bond strength of orthodontic brackets bonded to high-translucent dental zirconia with different surface treatments: An in vitro study
  • Thomas Brown, Edwin Kee, Xiaoming Xu, Andrew Chapple, Charles Stamitoles, Paul Armbruster, Richard W. Ballard

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.