S'abonner

Optimal chest compression for cardiac arrest until the establishment of ECPR: Secondary analysis of the SAVE-J II study - 19/03/24

Doi : 10.1016/j.ajem.2024.01.013 
Futoshi Nagashima a, , Satoshi Inoue b , Tomohiro Oda a , Tomohiro Hamagami a , Tomoya Matsuda a , Makoto Kobayashi c , Akihiko Inoue d , Toru Hifumi e , Tetsuya Sakamoto f , Yasuhiro Kuroda g

The SAVE-J II study group

a Tajima Emergency and Critical Care Medical Center, Toyooka Public Hospital, Hyogo, Japan 
b Inoue Satoshi Clinic, Fukuoka, Japan 
c Emergency Medical Center, Tottori Prefectural Central Hospital, Tottori, Japan 
d Hyogo Emergency Medical Center, Department of Emergency and Critical Care Medicine, Hyogo, Japan 
e St. Luke's International Hospital, Department of Emergency and Critical Care Medicine, Tokyo, Japan 
f Teikyo University School of Medicine, Department of Emergency Medicine, Tokyo, Japan 
g Kagawa University Hospital, Department of Emergency, Disaster and Critical Care Medicine, Kagawa, Japan 

Corresponding author.

Abstract

Introduction

The widespread incorporation of extracorporeal cardiopulmonary resuscitation (ECPR) for out-of-hospital cardiac arrest requires the delivery of effective and high-quality chest compressions prior to the initiation of ECPR. The aim of this study was to evaluate and compare the effectiveness of mechanical and manual chest compressions until the initiation of ECPR.

Methods

This study was a secondary analysis of the Japanese retrospective multicenter registry “Study of Advanced Life Support for Ventricular Fibrillation by Extracorporeal Circulation II (SAVE-J II)”. Patients were divided into two groups, one receiving mechanical chest compressions and the other receiving manual chest compressions. The primary outcome measure was mortality at hospital discharge, while the secondary outcome was the cerebral performance category (CPC) score at discharge.

Results

Of the 2157 patients enrolled in the SAVE-J II trial, 453 patients (329 in the manual compression group and 124 in the mechanical compression group) were included in the final analysis. Univariate analysis showed a significantly higher mortality rate at hospital discharge in the mechanical compression group compared to the manual compression group (odds ratio [95% CI] = 2.32 [1.34–4.02], p = 0.0026). Multivariate analysis showed that mechanical chest compressions were an independent factor associated with increased mortality at hospital discharge (adjusted odds ratio [95% CI] = 2.00 [1.11–3.58], p = 0.02). There was no statistically significant difference in CPC between the two groups.

Conclusion

For patients with out-of-hospital cardiopulmonary arrest who require ECPR, extreme caution should be used when performing mechanical chest compressions.

Le texte complet de cet article est disponible en PDF.

Keywords : Extracorporeal cardiopulmonary resuscitation (ECPR), Out-of-hospital cardiac arrest, Mechanical chest compressions, Manual chest compressions, Discharge mortality, Cerebral performance category (CPC)


Plan


© 2024  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 78

P. 102-111 - avril 2024 Retour au numéro
Article précédent Article précédent
  • External validation of the “deformity, edema, and pain in pronation” model for predicting wrist fractures
  • Yesim Eyler, Mustafa Sever, Ali Turgut, Necmiye Yalcin Ocak, Ahmet Onata, Olcay Gürsoy
| Article suivant Article suivant
  • Ultrasound-guided nerve blocks in emergency medicine practice: 2022 updates
  • Andrew J. Goldsmith, Joseph Brown, Nicole M. Duggan, Tomer Finkelberg, Nick Jowkar, Joseph Stegeman, Matthew Riscinti, Arun Nagdev, Richard Amini

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.