S'abonner

Comparison of initial adenosine dose conversion rate for supraventricular tachycardia in the emergency department - 28/10/24

Doi : 10.1016/j.ajem.2024.08.044 
Nichole Krug, PharmD a, Paige Baize, PharmD a, Stephanie Barre, PharmD a, Robert Barnes, MD b, Katherine Weigartz, PharmD a,
a Baylor University Medical Center, Department of Pharmacy, 3500 Gaston Avenue, Dallas, TX 75246, United States of America 
b Baylor University Medical Center, Department of Emergency Medicine, 3500 Gaston Avenue, Dallas, TX 75246, United States of America 

Corresponding author.

Abstract

Objective

To evaluate the rate of supraventricular tachycardia (SVT) termination between 6 mg and 12 mg initial adenosine doses.

Methods

This multi-center, retrospective cohort study evaluated patients presenting to the emergency department (ED) from January 1, 2020 to June 30, 2022 in SVT and received adenosine. The primary objective of the study is to compare the rate of SVT termination between adenosine 6 mg and 12 mg as documented on a formal electrocardiogram. Secondary endpoints include termination of SVT with subsequent adenosine dose, time to ED disposition, adverse effects, and subgroup analyses of patients with a body mass index greater than or equal to 40 kg/m2 and a history of SVT.

Results

Of 213 patients included, a 6 mg initial adenosine dose was administered to 117 patients (54.9 %) and a 12 mg initial adenosine dose was administered to 96 patients (45.1 %). SVT termination following the initial dose of 6 mg or 12 mg was 56.4 % and 79.1 %, respectively (p < 0.001). Among the 46 patients who failed to terminate SVT with an initial 6 mg dose, 33 converted to sinus rhythm with a subsequent adenosine dose in comparison to 1 of the 7 patients receiving an initial dose of 12 mg (71.7 % vs 14.3 %, p = 0.007). Median time to ED disposition, either inpatient admission or discharge, was 209 and 161 min, respectively (p = 0.104). There was no statistical difference in either subgroup analyses.

Conclusion

A higher rate of SVT termination was observed with an initial adenosine dose of 12 mg in the ED in comparison to the guideline recommended dose of 6 mg. There were no significant differences in adverse effects observed.

Le texte complet de cet article est disponible en PDF.

Keywords : Supraventricular tachycardia, SVT, Adenosine, Termination, Sinus rhythm, Emergency department


Plan


© 2024  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 85

P. 117-122 - novembre 2024 Retour au numéro
Article précédent Article précédent
  • Using machine learning to predict bacteremia in urgent care patients on the basis of triage data and laboratory results
  • Chung-Ping Chiu, Hsin-Hung Chou, Peng-Chan Lin, Ching-Chi Lee, Sun-Yuan Hsieh
| Article suivant Article suivant
  • A nationwide analysis of emergency medicine residents' CT interpretation in trauma: The Tract-EM study
  • Mehmet Ali Aslaner, Gültekin Kadı, Sevcihan Kesen, Atiye Cenay Karabörk Kılıç, Özlem Coşkun, Fikret Bildik, Ayfer Keleş, Ahmet Demircan, Hüseyin Koray Kılıç, Burak Şişik, Ömer Faruk Korkak, Gülhan Kurtoğlu Çelik, Volkan Arslan, Alten Oskay, Özge Can, Necmi Baykan, Secdegül Coşkun Yaş, Merve Yazla, Elif Yaka, Mehmet Göktuğ Efgan, Melih İmamoğlu, Ahmet Ak, Ayça Koca, Fatih Çalışkan, Metin Yadigaroğlu, Serkan Emre Eroğlu, Süleyman İbze, Mahmut Yaman, Mahmut Taş, Şenol Ardıç, Nalan Kozacı, Yunsur Çevik, Mustafa Sabak, Ali Aygün, Mehmet Koşargelir, Yusuf Ertuğrul Aslan, Gürkan Altuntaş, Nurdan Acar, Buğra İlhan, The TraCT-EM study group

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.