Diagnostic accuracy of artificial intelligence for identifying systolic and diastolic cardiac dysfunction in the emergency department - 13/12/24

Doi : 10.1016/j.ajem.2024.10.019 
Michael Gottlieb, MD , Evelyn Schraft, MD, James O'Brien, MD, Daven Patel, MD, MPH
 Department of Emergency Medicine, Rush University Medical Center, Chicago, IL, United States of America 

Corresponding author.

Abstract

Introduction

Cardiac point-of-care ultrasound (POCUS) can evaluate for systolic and diastolic dysfunction to inform care in the Emergency Department (ED). However, accurate assessment can be limited by user experience. Artificial intelligence (AI) has been proposed as a model to increase the accuracy of cardiac POCUS. However, there is limited evidence of the accuracy of AI in the clinical environment. The objective of this study was to determine the diagnostic accuracy of AI for identifying systolic and diastolic dysfunction compared with expert reviewers.

Methods

This was a prospective, observational study of adult ED patients aged ≥45 years with risk factors for systolic and diastolic dysfunction. Ultrasound fellowship-trained physicians used an ultrasound machine with existing AI software and obtained parasternal long axis, parasternal short axis, and apical 4-chamber views of the heart. Systolic dysfunction was defined as ejection fraction (EF) < 50 % in at least two views using visual assessment or E-point septal separation >10 mm. Diastolic dysfunction was defined as an E:A < 0.8, or ≥ 2 of the following: septal e' < 7 cm/s or lateral e' < 10 cm/s, E:e' > 14, or left atrial volume > 34 mL/m2. AI was subsequently used to measure EF, E, A, septal e', and lateral e' velocities. The gold standard was systolic or diastolic dysfunction as assessed by two independent physicians with discordance resolved via consensus. We performed descriptive statistics (mean ± standard deviation) and calculated the sensitivity, specificity, positive likelihood ratio (LR+), and negative likelihood ratio (LR-) of the AI in determining systolic and diastolic dysfunction with 95 % confidence interval (CI). Subgroup analyses were performed by body mass index (BMI).

Results

We enrolled 220 patients, with 11 being excluded due to inadequate images, resulting in 209 patients being included in the study. Mean age was 60 ± 9 years, 51.7 % were women, and the mean BMI was 31 ± 8.1 mg/kg2. For assessing systolic dysfunction, AI was 85.7 % (95 %CI 57.2 % to 98.2 %) sensitive and 94.8 % (95 %CI 90.6 % to 97.5 %) specific with a LR+ of 16.4 (95 %CI 8.6 to 31.1) and LR- of 0.15 (95 % CI 0.04 to 0.54). For assessing diastolic dysfunction, AI was 91.9 % (95 %CI 85.6 % to 96.0 %) sensitive and 94.2 % (95 %CI 87.0 % to 98.1 %) specific with a LR+ of 15.8 (95 %CI 6.7 to 37.1) and a LR- of 0.09 (0.05 to 0.16). When analyzed by BMI, results were similar except for lower sensitivity in the BMI ≥ 30 vs BMI < 30 (100 % vs 80 %).

Conclusion

When compared with expert assessment, AI had high sensitivity and specificity for diagnosing both systolic and diastolic dysfunction.

Le texte complet de cet article est disponible en PDF.

Keywords : POCUS, Point-of-care ultrasound, Ultrasound, Artificial intelligence, Heart failure, Systolic dysfunction, Diastolic dysfunction, Ejection fraction


Plan


© 2024  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 86

P. 115-119 - décembre 2024 Retour au numéro
Article précédent Article précédent
  • External evaluation of Brain Injury Guideline (BIG) low risk criteria for traumatic brain injury
  • Elena A. Puccio, Joshua B. Brown, Clifton W. Callaway, Adam N. Frisch, David O. Okonkwo, David J. Barton
| Article suivant Article suivant
  • High- versus low-dose ketamine for analgesia in older adults in the emergency department
  • Alexander D. Ginsburg, Heather A. Heaton, Aeryana Beaudrie-Nunn, Lucas Oliveira J. e Silva, Elizabeth Canterbury, Caitlin S. Brown, Allyson K. Palmer, Kristin C. Cole, Erin D. Wieruszewski, Fernanda Bellolio

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.