S'abonner

A comparative assessment of the BioBiteCorrector® and Herbst appliances combined with fixed appliances in class II patients: A retrospective cohort study on PAR and IOTN indices - 14/03/25

Doi : 10.1016/j.ortho.2025.100994 
Nick Schröder 1, Eleni K. Alexopoulou 1, Tim Schröder 2, Alexandra K. Papadopoulou 3, 4, Vasiliki Koretsi 1,
1 Clinic of Orthodontics and Pediatric Dentistry, Center for Dental Medicine, University of Zurich, Zurich, Switzerland 
2 Private practice, Herisau, Switzerland 
3 Division of Orthodontics, Faculty of Medicine, University Clinics of Dental Medicine, University of Geneva, Geneva, Switzerland 
4 Discipline of Orthodontics, School of Dentistry, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia 

Vasiliki Koretsi, Clinic of Orthodontics and Pediatric Dentistry, Plattenstrasse 11, 8032 Zurich, Switzerland.Clinic of Orthodontics and Pediatric DentistryPlattenstrasse 11Zurich8032Switzerland

Summary

Purpose

The BioBiteCorrector® (BBC) appliance was introduced as a further development of the Herbst appliance; however, there is no research comparing their treatment outcomes.

Materials and methods

Caucasian healthy patients with at least 5mm overjet were included and treated with either Herbst or BBC, both combined with fixed appliances, by one experienced orthodontist at a private practice in Switzerland. Treatment effectiveness was evaluated in terms of occlusal outcomes via the Peer Assessment Rating (PAR) and Index of Orthodontic Treatment Need (IOTN) indices, for which groups were matched at baseline. Data collection took place before bonding and after debonding and data was statistically analyzed with linear/logistic regressions at 5%.

Results

Each group was comprised of 58 patients. Patient and treatment related characteristics did not demonstrate any clinically relevant differences at baseline. The overall treatment duration was 19.3±5.3 and 22.9±5.7 months for the Herbst and BBC respectively (P<0.001). The main outcomes of absolute PAR reduction, % PAR reduction, PAR improvement, or great PAR improvement were not statistically significant between groups (P>0.05 in all instances); however, patients treated with Herbst had slightly worse overall IOTN scores (P<0.03). The findings did not significantly change after controlling for confounders.

Conclusion

Both Herbst and BBC appeared to be equally effective in improving class II malocclusion, yet the BBC appliance led to slightly longer overall treatment duration.

Le texte complet de cet article est disponible en PDF.

Keywords : Class II malocclusion, Functional appliances, Herbst, BioBiteCorrector®, PAR index, IOTN index, Cohort study


Plan


© 2025  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 23 - N° 2

Article 100994- juin 2025 Retour au numéro
Article précédent Article précédent
  • Comparison of self-perception in relation to the normative need for orthodontic treatment in a population of dental students in Brazil: A cross-sectional study
  • Luciana Rougemont Squeff, Flavio Copello, Guido Artemio Marañón-Vásquez, Ronir Raggio Luiz, Lincoln Nojima, Matilde da Cunha Gonçalves Nojima
| Article suivant Article suivant
  • Effect of archwire size and lever arm length on anterior and posterior teeth movement during en-masse retraction in personalized lingual orthodontics: A 3-dimensional finite element study
  • Lin Lu, Yafen Zhu, Naiqun Yu, Li Xu, Xiaoyan Chen

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.