Abstract

Background

Subaortic stenosis is an aortic disease characterised by the presence of a membrane located at the aortic valve inlet, that causes a sudden reduction of the inflow lumen. The membrane develops as a tissue growth of variable thickness that can cause a major increase in the pressure gradient. In this case, when diagnosed, it is removed by surgical resection.

Methods

To investigate the haemodynamic alteration introduced by subaortic membranes, an in vitro study was designed and performed. Stiff and flexible membranes were implanted at the inlet of a bioprosthetic control valve. These mock membranes had different radial and angular alignment, modelling concentric and eccentric orifice positions. For each configuration, a range of different membrane extensions was studied, progressively reducing the orifice area at the inlet of the control valve.

Results

Analysis of the hydrodynamic performances indicates that the detrimental effect of subaortic membranes becomes significant when the membrane orifice areas reduce below 75% of the unobstructed inflow lumen. Video analysis of the valve leaflets dynamics indicates that, together with a worsening in the systolic pressure gradient, the presence of subaortic membranes increases cusps fluttering. As the membrane orifice area reduces, leaflets experience faster oscillation frequencies at decreasing amplitudes.

Conclusions

The fibromuscular or thin nature of the membrane has a significant role on the severity of the pathology, with higher stiffnesses generally producing worse hydrodynamics. The orifice dimension and position are also important on the systolic performance and can determine potential structural degradation and haematic damage.

Le texte complet de cet article est disponible en PDF.

Graphical abstract




Le texte complet de cet article est disponible en PDF.

Highlights

Subaortic stenosis can significantly worsen the performance of the aortic valve.
Membrane thickness and orifice size are crucial factors in disease severity.
Membrane can increase leaflet fluttering, potentially leading to blood damage.
A critical membrane size was identified, above which the impact becomes significant.
In-vitro studies can help understand the complex effects of subaortic stenosis.

Le texte complet de cet article est disponible en PDF.

Keywords : Subaortic stenosis, Subaortic membrane, In vitro analysis, Hydrodynamic performance, Leaflet fluttering


Plan


© 2025  AGBM. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 46 - N° 4

Article 100897- août 2025 Retour au numéro
Article précédent Article précédent
  • Effectiveness of 3D Technology-Assisted Minimally Invasive Surgery for Brainstem Hemorrhage
  • Xiaofeng Zhu, Lei Xia, Quan Chen, Jin Shang, Qiang Tong, Jinlong Zheng, Xiangyang Tian, Xiu Yang, Qiu Han
| Article suivant Article suivant
  • Characterization and In Vivo Evaluation of Phosphate-Based Glass/TiO2 for Skull Prosthetic Application
  • Ana Lucía Sánchez-Alfonso, Lorena Gaytán-Tocavén, Luz Eugenia Alcantara-Quintana, Raul Gerardo Paredes, Criseida Ruiz-Aguilar

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.