Comparative evaluation of optical property changes in direct printed aligners using two resins: An in vivo investigation - 06/12/25

Doi : 10.1016/j.ortho.2025.101106 
Subashree Ravichandran ⁎ , ShanthiniPriya Arumugam, Balaji Krishnan, Parameswaran TM, Mahalakshmi Krishnakumaran, Aswini Soundharya Sekar
 Department of Orthodontics, Tagore Dental College, Chennai 600127, India 

⁎ Subashree R, Department of Orthodontics, Tagore Dental College, Chennai 600127, India. Department of Orthodontics, Tagore Dental College Chennai 600127 India

Summary

Objective

Understanding the behaviour of different printable resins under clinical simulation is essential for optimal material selection. The study aims to evaluate and compare the optical behaviour of aligners printed using directed printed resins, TA 28 and TC 85.

Material and methods

Study consisted of two groups Group 1 – aligners printed using TC 85 and Group 2 – aligners printed using TA 28 resin. Aligners were designed using Direct Aligner Designer (DAD) software and fabricated with a uniform 0.5 mm thickness. Patients with Class I molar relationships, mild crowding, minimal rotation, and no history of periodontal disease were included in this study. Maxillary intraoral scans were performed using the Aoralscan 3 scanner. Aligners were printed using TA-28 and TC-85 resins and post-cured for 24 minutes with the Tera Harz Cure THC unit (405 nm UV LED). Aligners were air-dried and patients were instructed to wear the aligner for 14 days for 20–22 hrs. Control (unused) samples were fabricated alongside for comparison.

Results

Shapiro–Wilk test confirmed normal data distribution; thus, paired and independent t -tests were applied. Intragroup comparisons showed statistically significant changes (p < 0.001) in all colour parameters (L*, a*, b*) after 14 days of wear in both groups. Intergroup analysis revealed no significant difference in L* values for unused (p = 0.07) or used aligners (p = 0.89). However, a* and b* values differed significantly between the groups (p < 0.001). The mean colour difference (ΔE) between groups was not statistically significant in either condition (p = 0.592).

Conclusion

Aligners printed with TC-85 and TA-28 resins exhibited clinically acceptable colour stability after intraoral use, with ΔE values within aesthetic thresholds. TA-28 showed slightly greater colour change, which may reflect differences in material composition and could inform clinical material selection.

Le texte complet de cet article est disponible en PDF.

Keywords : Orthodontics, Aligner, Optical properties, Colour stability, TC-85, TA-28, Intraoral aging


Plan


© 2025  CEO. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 24 - N° 2

Article 101106- juin 2026 Retour au numéro
Article précédent Article précédent
  • Assessing colour stability of direct printed and thermoformed aligners: An in vitro study on aesthetics longevity
  • Bhavani Priya Perumalla, Pradeep Kandikatla, Arun Bhupathi, Anoosha Manda, Praveen Kumar Varma, Hari Babu
| Article suivant Article suivant
  • Non-surgical treatment of adult skeletal class III patient with severe alveolar bone loss by sequential segmental displacement and third molar extraction: A case report
  • Hyeon Gi Hong, Hieu Nguyen, Amani Alkhamees, Kee-Joon Lee

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.