Abstract

Background

High respiratory drive in mechanically ventilated patients with spontaneous breathing effort may cause excessive lung stress and strain and muscle loading. Therefore, it is important to have a reliable estimate of respiratory effort to guarantee lung and diaphragm protective mechanical ventilation. Recently, a novel non-invasive method was found to detect excessive dynamic transpulmonary driving pressure (∆ P L ) and respiratory muscle pressure ( P mus ) with reasonable accuracy. During the Coronavirus disease 2019 (COVID-19) pandemic, it was impossible to obtain the gold standard for respiratory effort, esophageal manometry, in every patient. Therefore, we investigated whether this novel non-invasive method could also be applied in COVID-19 patients.

Methods

P L and P mus were derived from esophageal manometry in COVID-19 patients. In addition, ∆ P L and P mus were computed from the occlusion pressure (∆ P occ ) obtained during an expiratory occlusion maneuver. Measured and computed ∆ P L and P mus were compared and discriminative performance for excessive ∆ P L and P mus was assessed. The relation between occlusion pressure and respiratory effort was also assessed.

Results

Thirteen patients were included. Patients had a low dynamic lung compliance [24 (20–31) mL/cmH 2 O], high ∆ P L (25 ± 6 cmH 2 O) and high P mus (16 ± 7 cmH 2 O). Low agreement was found between measured and computed ∆ P L and P mus . Excessive ∆ P L   >  20 cmH 2 O and P mus   >  15 cmH 2 O were accurately detected (area under the receiver operating curve (AUROC) 1.00 [95% confidence interval (CI), 1.00–1.00], sensitivity 100% (95% CI, 72–100%) and specificity 100% (95% CI, 16–100%) and AUROC 0.98 (95% CI, 0.90–1.00), sensitivity 100% (95% CI, 54–100%) and specificity 86% (95% CI, 42–100%), respectively). Respiratory effort calculated per minute was highly correlated with ∆ P occ (for esophageal pressure time product per minute (PTP es/min ) r 2  = 0.73; P  = 0.0002 and work of breathing (WOB) r 2  = 0.85; P   <  0.0001).

Conclusions

P L and P mus can be computed from an expiratory occlusion maneuver and can predict excessive ∆ P L and P mus in patients with COVID-19 with high accuracy.

Le texte complet de cet article est disponible en PDF.

Keywords : Coronavirus disease 2019, Respiratory monitoring, Occlusion pressure, Dynamic transpulmonary pressure, Respiratory muscle pressure, Respiratory effort


Plan


© 2021  The Author(s) 2021. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 11 - N° 1

Article 26- 2021 Retour au numéro
Article précédent Article précédent
  • Dobutamine-sparing versus dobutamine-to-all strategy in cardiac surgery: a randomized noninferiority trial
  • Rafael Alves Franco, Juliano Pinheiro de Almeida, Giovanni Landoni, Thomas W.L. Scheeren, Filomena Regina Barbosa Gomes Galas, Julia Tizue Fukushima, Suely Zefferino, Pasquale Nardelli, Marilde de Albuquerque Piccioni, Elisandra Cristina Trevisan Calvo Arita, Clarice Hyesuk Lee Park, Ligia Cristina Camara Cunha, Gisele Queiroz de Oliveira, Isabela Bispo Santos da Silva Costa, Roberto Kalil Filho, Fabio Biscegli Jatene, Ludhmila Abrahão Hajjar
| Article suivant Article suivant
  • Non-invasive ventilation alternating with high-flow nasal oxygen versus high-flow nasal oxygen alone after extubation in COPD patients: a post hoc analysis of a randomized controlled trial
  • Arnaud W. Thille, Rémi Coudroy, Mai-Anh Nay, Arnaud Gacouin, Maxens Decavèle, Romain Sonneville, François Beloncle, Christophe Girault, Laurence Dangers, Alexandre Lautrette, Quentin Levrat, Anahita Rouzé, Emmanuel Vivier, Jean-Baptiste Lascarrou, Jean-Damien Ricard, Keyvan Razazi, Guillaume Barberet, Christine Lebert, Stephan Ehrmann, Alexandre Massri, Jeremy Bourenne, Gael Pradel, Pierre Bailly, Nicolas Terzi, Jean Dellamonica, Guillaume Lacave, René Robert, Stéphanie Ragot, Jean-Pierre Frat, for the HIGH-WEAN Study Group, for the REVA Research Network, Florence Boissier, Maeva Rodriguez, Faustine Reynaud, Delphine Chatellier, Céline Deletage, Carole Guignon, Florent Joly, Anne Veinstein, Dalila Benzekri-Lefevre, Thierry Boulain, Grégoire Muller, Yves Le Tulzo, Jean-Marc Tadié, Adel Maamar, Suela Demiri, Julien Mayaux, Alexandre Demoule, Lila Bouadma, Claire Dupuis, Pierre Asfar, Marc Pierrot, Gaëtan Béduneau, Déborah Boyer, Benjamin Delmas, Bérénice Puech, Konstantinos Bachoumas, Edouard Soum, Séverin Cabasson, Marie-Anne Hoppe, Saad Nseir, Olivier Pouly, Gaël Bourdin, Sylvène Rosselli, Anthony Le Meur, Charlotte Garret, Maelle Martin, Guillaume Berquier, Abirami Thiagarajah, Guillaume Carteaux, Armand Mekontso-Dessap, Antoine Poidevin, Anne-Florence Dureau, Marie-Ange Azais, Gwenhaël Colin, Emmanuelle Mercier, Marlène Morisseau, Caroline Sabatier, Walter Picard, Marc Gainnier, Thi-My-Hue Nguyen, Gwenaël Prat, Carole Schwebel, Matthieu Buscot

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.