S'abonner

Effects of intraoral ageing on the mechanical and surface properties of clear aligner materials: A systematic review - 01/09/26

Doi : 10.1016/j.ortho.2026.101234 
Srinidhi Ramasundaram 1, , Raja Subramani 1, Dilip Srinivasan 2
1 Department of Orthodontics and Dentofacial Orthopedics, KSR Institute of Dental Science and Research, Tamil Nadu, India 
2 Department of Orthodontics and Dentofacial Orthopedics, SRM Dental College, Bharathi Salai, Ramapuram, Chennai, Tamil Nadu, India 

Srinidhi Ramasundaram, Department of Orthodontics and Dentofacial Orthopedics, KSR Institute of Dental Science and Research, Tamil Nadu, India. Srinidhi Ramasundaram, Department of Orthodontics and Dentofacial Orthopedics, KSR Institute of Dental Science and Research Tamil Nadu India

Highlights

Intraoral ageing affected all evaluated clear aligner materials.
Material deterioration varied according to aligner composition and manufacturing process.
Directly printed aligners showed increased relaxation index after intraoral use.
PETG thermoformed aligners generally demonstrated favourable mechanical behaviour.
Standardized clinical retrieval studies are needed to strengthen the evidence base.

Le texte complet de cet article est disponible en PDF.

Summary

Objective

The aim of this study was to systematically investigate the changes in the material properties and surface morphology of different aligner materials following intraoral use.

Material- and methods

A search was conducted on five databases and was based on PRISMA guidelines. Only clinical retrieval studies involving ex vivo analysis of aligners following intraoral use, published in English, were included. Risk of bias assessment was done using the modified Cochrane Risk of Bias Tool tailored for this systematic review, which had seven domains.

Results

This review included fourteen studies. Risk of bias assessment revealed four studies showed a moderate risk and ten studies showed a high risk. Among the selected articles, eight studied Invisalign® appliances, five studied thermoformed aligners, six studied directly printed aligners, and one studied ClearCorrect® aligners. Although statistical significance varied across studies, all the materials showed material degradation with intraoral use, with directly printed aligners exhibiting an increased relaxation index. Mixed results were obtained in surface characteristics with surface irregularities after use. Compositional analysis indicated hydrolysis of PETG aligners.

Conclusion

The intraoral exposure contributed to the deterioration of the mechanical properties, dimensional stability, and surface characteristics of all the aligner systems. But the extent of these alterations varied based on the manufacturing process and material composition. None of the aligner systems could be defined as ideal, as their clinical performance is determined by fabrication procedure, intrinsic material characteristics, and intraoral factors. And thus, clinical findings should be interpreted with caution, and further high-quality standardised research is essential to obtain clinical significance.

Le texte complet de cet article est disponible en PDF.

Keywords : Clear aligners, Directly printed aligners, Intraoral ageing, Material degradation, Mechanical properties, Surface morphology


Plan


© 2026  CEO. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 24 - N° 4

Article 101234- décembre 2026 Retour au numéro
Article précédent Article précédent
  • Clinical, biomechanical, and digital factors associated with refinement after the first series of clear aligners: A systematic review
  • Karla Nogueira Matos, Tainá Belline da Silva, Leonardo Matos de Faria Almeida, Marcos de Faria Almeida, Hugo Henrique dos Santos Dantas Guimarães
| Article suivant Article suivant
  • Diagnostic performance of artificial intelligence for orthodontic and dentofacial assessment using 2D and 3D facial images: A systematic review
  • Hugo Henrique dos Santos Dantas Guimarães, Karla Nogueira Matos

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.