S'abonner

Procedure-related, false-positive cytology results during EUS-guided FNA in patients with esophageal cancer - 24/08/11

Doi : 10.1016/j.gie.2010.01.051 
Bettien M. van Hemel, MD , Alexander A. Lamprou, MD, Rinse Weersma, MD, John T.M. Plukker, MD, PhD, Albert J.H. Suurmeijer, MD, PhD, Hendrik M. van Dullemen, MD, PhD
Current affiliations: Departments of Pathology (B.M.v.H., A.J.H.S.), Gastroenterology (A.A.L., R.W., H.M.v.D.), and Surgery (J.T.M.P.), University Medical Center Groningen, Groningen, The Netherlands 

Reprint requests: BM van Hemel, MD, Department of Pathology, University Medical Center Groningen, P.O. Box 30001, 9700 RB Groningen, The Netherlands

Résumé

Background

EUS is a standard staging procedure in esophageal cancer. For adequate staging, FNA of suspicious lymph nodes is recommended. Based on optimal staging, sophisticated treatment can be applied more properly. The working channel of the endoscope can potentially be contaminated by cancer cells derived from the luminal surface of esophageal cancer during EUS-guided FNA, which may result in false-positive cytology results of EUS-guided FNA of celiac lymph nodes.

Objective

To determine whether passing an endoscope through intraluminal esophageal cancer can lead to contamination of the working channel with tumor cells.

Design

An ex vivo assessment of contamination of endoscope working channels.

Setting

University hospital.

Patients

This study involved 13 patients with esophageal cancer.

Intervention

Working channels of endoscopes that had been used in patients with intraluminal esophageal cancer were studied immediately after EUS. A routine ex vivo FNA was performed through the endoscope on 8 patients. The same procedure was performed through the endoscope on 5 other patients after the working channel had been cleaned by extensive flushing.

Main Outcome Measurements

Semiquantitative scoring of cytology smears.

Results

Six of 8 specimens contained carcinoma cells. No contamination by carcinoma cells or normal cells was observed when the working channel was flushed with tap water prior to the sham FNA procedure.

Limitations

This was an ex vivo study of a limited group of patients.

Conclusion

The working channel of the endoscope can be contaminated during the EUS-guided FNA procedure. Cancer cell contamination can be avoided by flushing the endoscope.

Le texte complet de cet article est disponible en PDF.

Plan


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication.


© 2010  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 71 - N° 7

P. 1130-1133 - juin 2010 Retour au numéro
Article précédent Article précédent
  • Outcomes of a combined antegrade and retrograde approach for dilatation of radiation-induced esophageal strictures (with video)
  • Evan S. Dellon, Nicole R. Cullen, Ryan D. Madanick, Robert A. Buckmire, Ian S. Grimm, Mark C. Weissler, Marion E. Couch, Nicholas J. Shaheen
| Article suivant Article suivant
  • Comparing the Blatchford and pre-endoscopic Rockall score in predicting the need for endoscopic therapy in patients with upper GI hemorrhage
  • Sandy H. Pang, Jessica Y.L. Ching, James Y.W. Lau, Joseph J.Y. Sung, David Y. Graham, Francis K.L. Chan

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.