S'abonner

Five-year results of a randomized, prospective, clinical trial of diode vs argon laser trabeculoplasty for open-angle glaucoma - 09/09/11

Doi : 10.1016/S0002-9394(98)00151-2 
Paul Y Chung, MD a, Joel S Schuman, MD b, , Peter A Netland, MD, PhD c, Rhea A Lloyd-Muhammad, MD b, Deborah S Jacobs, MD d
a Inland Eye Institute, Loma Linda University School of Medicine, Loma Linda, California, USA (Dr Chung) 
b New England Eye Center, Tufts University School of Medicine, Boston, Massachusetts, (Drs Schuman and Lloyd-Muhammad) USA 
c Massachusetts Eye and Ear Infirmary, Harvard Medical School (Dr Netland) Boston, Massachusetts, USA 
d Beth Israel Medical Center, Harvard Medical School, Brookline (Dr Jacobs), Massachusetts, USA 

*Reprint requests to Joel S. Schuman, MD, New England Eye Center, 750 Washington St, Box 450, Boston, MA 02111; fax: (617) 636-4866)

Abstract

PURPOSE: To evaluate the safety and efficacy of laser trabeculoplasty (LTP) with a semiconductor diode laser (810 nm, [DLT]) vs an argon blue-green laser (488 to 514 nm, [ALT]).

METHODS: In a prospective, randomized clinical trial, 50 eyes of 46 patients with uncontrolled open-angle glaucoma on maximally tolerated medical therapy were treated and followed at regular intervals for 5 years. Fifty laser spots were applied over 180 degrees using either maximal laser power or sufficient power to produce blanching or a small bubble (570 to 850 mW, DLT; 400 to 1,100 mW, ALT). We performed DLT using a 100-μm spot size, a 0.5-second exposure, and a Ritch lens; we conducted ALT with a 50-μm spot, a 0.1-second exposure, and a Goldmann lens. Patients in the study were followed until trabeculectomy was required.

RESULTS: The mean follow-up times ± SD for all eyes were 38.6 ± 5.4 months, DLT (n = 22; range, 1 to 68 months) and 35.5 ± 4.8 months, ALT (n = 28; range, 1 to 66 months). Those in the diode laser group (n = 16) who had more than 1 year of follow-up were tracked for 49.4 months, and those in the argon laser group (n = 21) were tracked for 45.8 months. There were no significant differences in the mean pretreatment intraocular pressures (IOPs): 21.2 mm Hg, DLT (n = 22) and 21.5, ALT 21.5 mm Hg (n = 28); P = .81] or in mean final IOPs (15.7 mm Hg, DLT and 17.1 mm Hg, ALT; P = .19). Time to surgical failure showed no significant differences, with 50% of the DLT eyes and 58% of the ALT eyes surviving at 5 years (P = .59).

CONCLUSION: In eyes with open-angle glaucoma and unsatisfactory IOP control on maximally tolerated medical therapy, DLT and ALT are equally effective in lowering IOP over a 5-year period.

Le texte complet de cet article est disponible en PDF.

Plan


© 1998  Elsevier Science Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 126 - N° 2

P. 185-190 - août 1998 Retour au numéro
Article précédent Article précédent
  • Intraoperative crystallization on the intraocular lens surface
  • Randall J. Olson, Karin D. Caldwell, Alan S. Crandall, Michael K. Jensen, Shao-Chie Huang
| Article suivant Article suivant
  • Combined effect of dorzolamide and latanoprost on the rate of aqueous humor flow
  • Benjamin D Vanlandingham, Richard F Brubaker

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.