S'abonner

Nocturnal differences in subcutaneous tissue glucose between forearm and abdominal sites during continuous glucose monitoring in normal subjects - 17/02/08

Doi : DM-09-2005-31-4-1262-3636-101019-200515039 

A Von Dobeln [1],

U Adamson [1],

PE Lins [1]

Voir les affiliations

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Différences entre les concentrations de glucose du tissu sous-cutané de l'avant-bras et de l'abdomen lors d'un enregistrement continu du glucose nocturne chez des individus non-diabétiques

Objectifs

De nombreuses études à court terme utilisant le système de mesure du glucose en continu (CGMS) montrent qu'une amélioration du contrôle métabolique est obtenue chez les patients atteints d'un diabète de type 1 quand le CGMS est appliqué en clinique.

Bon nombre de données suggèrent que des mesures isolées de la glycémie avec une fréquence de 4 fois par jour parviennent à détecter moins de 70% de tous les épisodes hypoglycémiques mesurés par CGMS. Cependant l'augmentation de la fréquence des mesures de la glycémie a permis de mettre en doute l'hypoglycémie nocturne détectée par CGMS. Comme la plupart des études réalisées avec CGMS sont fondées sur des mesures à partir des tissus sous-cutanés de l'abdomen, nous avons vérifié si les résultats de senseurs placés à des endroits différents sont en accord avec la mesure de la glycémie veineuse.

Matériels et méthodes

Deux senseurs viscosimétriques du glucose, destinés au tissu sous-cutané de l'avant-bras et de l'abdomen, furent placés chez 12 individus non-diabétiques. Les mesures de glucose des senseurs furent relevées à 3 minutes d'intervalle. Le glucose sanguin veineux fut mesuré en duplicate par HemoCue toutes les 15-90 minutes pendant 24 heures. Chaque sujet consomma 3 repas riches en glucides, fit un test d'exercice et fut observé pendant un repos nocturne au centre de recherche.

Résultats

La diminution initiale de la glycémie pendant un exercice ne fut pas détectée de façon aussi marquée par les senseurs. En outre il n'y avait pas de différences significatives entre les mesures des senseurs et la glycémie pendant la journée. Enfin pendant un repos nocturne les mesures des senseurs abdominaux se révélèrent d'environ 20 % inférieures à celles de la glycémie et des senseurs de l'avant-bras.

Conclusion

Chez des non-diabétiques en repos nocturne, les résultats de la mesure des concentrations de glucose des tissus sous-cutanés de l'abdomen sont significativement inférieurs à ceux du glucose sanguin et du tissu sous-cutané de l'avant bras.

Nocturnal differences in subcutaneous tissue glucose between forearm and abdominal sites during continuous glucose monitoring in normal subjects

Objective

A number of short-term studies using the continuous glucose monitoring system (CGMS) indicate that improved metabolic control can be observed in patients with type 1 diabetes when CGMS is applied in clinical practice. Data have also accumulated to suggest that spot measurements of glucose performed four times a day would not detect as much as 70% of all hypoglycaemic episodes registered by CGMS. When more frequent reference values were obtained however it was inferred that nighttime hypoglycaemia reported by CGMS may be spurious. As most assessments with CGMS have been utilizing abdominal subcutaneous tissue, we were interested to evaluate whether differences between blood glucose and sensor readings obtained from different sites exist.

Research design and methods

Two viscometric affinity glucose sensors, applicable to subcutaneous tissue of both forearm and abdomen, were inserted subcutaneously in 12 non-diabetic subjects. Sensors generated glucose data at 3 min intervals and venous blood glucose was determined in duplicates by HemoCue at 15-90 min intervals for 24 hours. Each subject consumed three carbohydrate-rich meals, performed an exercise test, and was observed during nocturnal bed-rest at the research center.

Results

The initial decrease of blood glucose during exercise was not fully detected by the sensors. Otherwise, no significant differences between sensor values and blood glucose were observed during day-time. During nocturnal bed-rest abdominal sensor values came approximately 20% lower than blood glucose (≪ 0.001) and forearm sensor readings.

Conclusion

It is concluded that a difference between glucose values obtained from abdominal and forearm subcutaneous fat can be observed during nocturnal bed-rest in non-diabetics.


Mots clés : Senseurs de glucose , Hypoglycémie , Nocturne , Pompe à insuline

Keywords: Glucose sensors , Hypoglycaemia , Nocturnal , CSII


Plan



© 2005 Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 31 - N° 4

P. 347-352 - septembre 2005 Retour au numéro
Article précédent Article précédent
  • Taurine modifies insulin signaling enzymes in the fructose-fed insulin resistant rats
  • AT Anitha Nandhini, V Thirunavukkarasu, CV Anuradha
| Article suivant Article suivant
  • Epidemiology of the metabolic syndrome in 2045 French military personnel (EPIMIL study)
  • B Bauduceau, F Baigts, L Bordier, P Burnat, F Ceppa, V Dumenil, O Dupuy, J P Le Berre, H Mayaudon, S Paillasson,

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.