Digital Tomosynthesis: A New Technique for Imaging Nephrolithiasis. Specific Organ Doses and Effective Doses Compared With Renal Stone Protocol Noncontrast Computed Tomography - 26/01/14

Doi : 10.1016/j.urology.2013.10.004 
Andreas Neisius a, b, Gaston M. Astroza c, Chu Wang d, e, Giao Nguyen d, Nicholas J. Kuntz a, Natalie Januzis d, e, Michael N. Ferrandino a, Terry T. Yoshizumi d, Glenn M. Preminger a, Michael E. Lipkin a,
a Division of Urologic Surgery, Duke University Medical Center, Durham, NC 
b Department of Urology, Universitätsmedizin Mainz, Johannes Gutenberg University, Mainz, Germany 
c Department of Urology, Universidad Católica de Chile, Santiago, Chile 
d Duke University Medical Center, Duke Radiation Dosimetry Laboratory, Durham, NC 
e Duke University Medical Center, Medical Physics Graduate Program, Durham, NC 

Reprint requests: Michael E. Lipkin, M.D., Division of Urologic Surgery, Duke University Medical Center, DUMC 3167, Durham, NC 27710.

Abstract

Objective

To determine organ-specific doses (ODs) and effective dose (ED) for digital tomosynthesis (DT) and compare it with our institutional renal stone protocol noncontrast computed tomography (NCCT).

Methods

A validated anthropomorphic male phantom was placed supine on a digital GE Definium 8000 radiological scanner. Thermoluminescent dosimeters were placed in 256 locations and used to measure OD. A routine DT study was performed consisting of 2 scout images and 1 tomographic sweep in a 14.2-degree arc over the phantom. Software is used to recreate a series of coronal images from the sweep. ODs were determined as the sum of the doses for the study. Equivalent doses were calculated by multiplying OD with the appropriate tissue weighting factor. ED is the summation of the equivalent doses. OD and ED were determined in a similar fashion (using dosimeters) for a renal stone protocol NCCT and doses were compared.

Results

ODs for DT are significantly lower compared with NCCT. The ED for NCCT is 3.04 ± 0.34 mSv. The calculated ED for DT is 0.87 ± 0.15 mSv (2 scouts at 0.17 mSv and 0.14 mSv and 1 sweep at 0.56 mSv), P <.0001.

Conclusion

DT exposes patients to substantially less radiation than NCCT. This is particularly true for radiation-sensitive organs. Further studies are needed to compare the sensitivity and specificity of DT as compared with NCCT. However, its low overall radiation dose makes it an ideal study for the follow-up of recurrent stone formers in the office setting.

Le texte complet de cet article est disponible en PDF.

Plan


 Financial Disclosure: Glenn M. Preminger is a consultant for Mission Pharmacal and Boston Scientific. Michael N. Ferrandino is a proctor for Intuitive Surgical, and Michael E. Lipkin is a consultant for Boston Scientific. The remaining authors declare that they have no relevant financial interests.
 Funding Support: This work was supported in part by a Ferdinand Eisenberger grant of the Deutsche Gesellschaft für Urologie (German Society of Urology), ID NeA1/FE-11 (Andreas Neisius) and by the Endourological Society and Cook Urological (Gaston Astroza).


© 2014  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 83 - N° 2

P. 282-287 - février 2014 Retour au numéro
Article précédent Article précédent
  • Flexible Ureteroscopy With a Ureteral Access Sheath: When to Stent?
  • Fabio Cesar Torricelli, Shubha De, Bryan Hinck, Mark Noble, Manoj Monga
| Article suivant Article suivant
  • Measurement of Ureteric Stone Diameter in Different Planes on Multidetector Computed Tomography – Impact on the Clinical Decision Making
  • Syed M. Nazim, M. Hammad Ather, Nadir Khan

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.