Scar tissue–guided left ventricular lead placement for cardiac resynchronization therapy in patients with ischemic cardiomyopathy: An acute pressure-volume loop study - 22/03/14

Doi : 10.1016/j.ahj.2014.01.004 
Gerben Jan de Roest, MD a, , LiNa Wu, MD a, Carel C. de Cock, MD, PhD a, Matthijs L. Hendriks, MPA a, Peter Paul H.M. Delnoy, MD, PhD b, Albert C. van Rossum, MD, PhD a, c, Cornelis P. Allaart, MD, PhD a
a Department of Cardiology, and Institute for Cardiovascular Research (ICaR-VU), VU University Medical Center, Amsterdam, The Netherlands 
b Department of Cardiology, Isala klinieken, Zwolle, The Netherlands 
c Interuniversity Cardiology Institute of the Netherlands (ICIN), Utrecht, The Netherlands 

Reprint requests: Gerben Jan de Roest, MD, VU University Medical Center, Department of Cardiology, De Boelelaan 1118, 1081 HV Amsterdam, The Netherlands.

Résumé

Background

Response to cardiac resynchronization therapy (CRT) is hampered by the extent and location of left ventricular (LV) scar tissue. It is commonly advised to avoid scar tissue while placing the LV lead. However, whether individual patients benefit from this strategy remains unclear.

Methods

Thirty-two CRT candidates with ischemic cardiomyopathy were enrolled from 2 successive clinical trials (TBS and E-pot study). Magnetic resonance imaging with late contrast enhancement was performed to assess location, degree and transmurality of LV scar tissue. Patients underwent invasive pressure-volume loop measurements to assess acute LV pump function changes during pacing at posterolateral (PL) and anterolateral LV sites.

Results

In the study population (26 [81%] men, ejection fraction [EF] 22% ± 8%, QRS 149 ± 20 milliseconds), baseline mean stroke work (SW) and dP/dtmax were 4.4 ± 2.2 L∙mmHg and 849 ± 212 mmHg/s, respectively. The extent of scar tissue was inversely related to the acute increase in SW during pacing (R = −0.53, P = .002). Stimulating PL scar tissue resulted in deterioration of pump function (∆SW −17% ± 17%, P = .018), whereas pacing PL viable tissue led to an increase in pump function (∆SW +62% ± 51%, P < .001). Switching from pacing at the location of scar tissue, irrespective of the scar location, to viable tissue showed a significant increase in SW (−8% ± 20% vs +20 ± 40, P = .004).

Conclusions

The extent of LV scar tissue is inversely related to acute pump function improvement during CRT. Pacing at the location of (transmural) scar tissue at any site of the LV will generally deteriorate LV pump function. Placing the LV lead over viable myocardium significantly improves pump function as compared with pacing at the location of scar tissue in patients with ischemic cardiomyopathy.

Le texte complet de cet article est disponible en PDF.

Plan


© 2014  Mosby, Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 167 - N° 4

P. 537-545 - avril 2014 Retour au numéro
Article précédent Article précédent
  • Clevidipine in acute heart failure: Results of the A Study of Blood Pressure Control in Acute Heart Failure—A Pilot Study (PRONTO)
  • W. Frank Peacock, Abhinav Chandra, Douglas Char, Sean Collins, Guillaume Der Sahakian, Li Ding, Lala Dunbar, Gregory Fermann, Gregg C. Fonarow, Norman Garrison, Ming-yi Hu, Patrick Jourdain, Said Laribi, Phillip Levy, Martin Möckel, Christian Mueller, Patrick Ray, Adam Singer, Hector Ventura, Mason Weiss, Alex Mebazaa
| Article suivant Article suivant
  • Acute echocardiographic optimization of multiple stimulation configurations of cardiac resynchronization therapy through quadripolar left ventricular pacing: A tailored approach
  • Leonardo Calò, Annamaria Martino, Ermenegildo de Ruvo, Monia Minati, Simona Fratini, Marco Rebecchi, Chiara Lanzillo, Alessandro Fagagnini, Alessio Borrelli, Lucia De Luca, Luigi Sciarra

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.