A Simple Risk Tool (the OBSERVANT Score) for Prediction of 30-Day Mortality After Transcatheter Aortic Valve Replacement - 15/05/14
, Marco Barbanti, MD a, b, Corrado Tamburino, MD, PhD a, b, Paola D'Errigo, MS c, Marco Ranucci, MD d, e, Gennaro Santoro, MD f, Francesco Santini, MD g, Francesco Onorati, MD g, Claudio Grossi, MD h, Remo Daniel Covello, MD i, Piera Capranzano, MD a, b, Stefano Rosato, MS c, Fulvia Seccareccia, MS con behalf of the
OBSERVANT Research Group
Abstract |
Risk stratification tools used in patients with severe aortic stenosis have been mostly derived from surgical series. Although specific predictors of early mortality with transcatheter aortic valve replacement (TAVR) have been identified, the prognostic impact of their combination is unexplored. We sought to develop a simple score, using preprocedural variables, for prediction of 30-day mortality after TAVR. A total of 1,878 patients from a national multicenter registry who underwent TAVR were randomly assigned in a 2:1 manner to development and validation data sets. Baseline characteristics of the 1,256 patients in the development data set were considered as candidate univariate predictors of 30-day mortality. A bootstrap multivariate logistic regression process was used to select correlates of 30-day mortality that were subsequently weighted and integrated into a scoring system. Seven variables were weighted proportionally to their respective odds ratios for 30-day mortality (glomerular filtration rate <45 ml/min [6 points], critical preoperative state [5 points], New York Heart Association class IV [4 points], pulmonary hypertension [4 points], diabetes mellitus [4 points], previous balloon aortic valvuloplasty [3 points], and left ventricular ejection fraction <40% [3 points]). The model showed good discrimination in both the development and validation data sets (C statistics 0.73 and 0.71, respectively). Compared with the logistic European System for Cardiac Operative Risk Evaluation in the validation data set, the model showed better discrimination (C statistic 0.71 vs 0.66), goodness of fit (Hosmer-Lemeshow p value 0.81 vs 0.00), and global accuracy (Brier score 0.054 vs 0.073). In conclusion, the risk of 30-day mortality after TAVR may be estimated by combining 7 baseline clinical variables into a simple risk scoring system.
Le texte complet de cet article est disponible en PDF.Plan
| See page 1857 for disclosure information. |
Vol 113 - N° 11
P. 1851-1858 - juin 2014 Retour au numéroBienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.
Déjà abonné à cette revue ?