S'abonner

Overall ED efficiency is associated with decreased time to percutaneous coronary intervention for ST-segment elevation myocardial infarction - 04/10/14

Doi : 10.1016/j.ajem.2014.07.006 
Christopher W. Jones, MD a, , Seema S. Sonnad, PhD b, James J. Augustine, MD c, Charles L. Reese, MD d
a Department of Emergency Medicine, Cooper Medical School of Rowan University, One Cooper Plaza, Suite 152, Camden, NJ 08103 
b Christiana Care Value Institute, Christiana Care Health System, Newark DE 
c Emergency Department Benchmarking Alliance and the Department of Emergency Medicine, Wright State University, Dayton OH 
d Emergency Department Benchmarking Alliance and the Department of Emergency Medicine, Christiana Care Health System, Newark DE 

Corresponding author. Tel.: +1 856 342 2627; fax: +1 856 968 8272.

Abstract

Background

Performance of percutaneous coronary intervention (PCI) within 90 minutes of hospital arrival for ST-segment elevation myocardial infarction patients is a commonly cited clinical quality measure. The Centers for Medicare and Medicaid Services use this measure to adjust hospital reimbursement via the Value-Based Purchasing Program. This study investigated the relationship between hospital performance on this quality measure and emergency department (ED) operational efficiency.

Methods

Hospital-level data from Centers for Medicare and Medicaid Services on PCI quality measure performance was linked to information on operational performance from 272 US EDs obtained from the Emergency Department Benchmarking Alliance annual operations survey. Standard metrics of ED size, acuity, and efficiency were compared across hospitals grouped by performance on the door-to-balloon time quality measure.

Results

Mean hospital performance on the 90-minute arrival to PCI measure was 94.0% (range, 42-100). Among hospitals failing to achieve the door-to-balloon time performance standard, median ED length of stay was 209 minutes, compared with 173 minutes among those hospitals meeting the benchmark standard (P < .001). Similarly, median time from ED patient arrival to physician evaluation was 39 minutes for hospitals below the performance standard and 23 minutes for hospitals at the benchmark standard (P < .001). Markers of ED size and acuity, including annual patient volume, admission rate, and the percentage of patients arriving via ambulance did not vary with door-to-balloon time.

Conclusion

Better performance on measures associated with ED efficiency is associated with more timely PCI performance.

Le texte complet de cet article est disponible en PDF.

Plan


 Meetings: This abstract was presented at the American College of Cardiology annual meeting on 3/10/2013 in San Francisco, CA, and the Society for Academic Emergency Medicine annual meeting on 5/17/2013 in Atlanta, GA.
☆☆ Grants/Disclosures: Dr Seema Sonnad is supported through grants from the University of Pennsylvania Research Foundation and from the University of Pennsylvania–Pfizer Collaborative. She has previously received consulting income from the Center for Medical Technology Policy and a grant from InHealth. No other authors have relevant disclosures.


© 2014  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 32 - N° 10

P. 1189-1194 - octobre 2014 Retour au numéro
Article précédent Article précédent
  • The physiological effects and quality of chest compressions during CPR at sea level and high altitude
  • Jen-Chun Wang, Shih-Hung Tsai, Yu-Long Chen, Chin-Wang Hsu, Kuan-Cheng Lai, Wen-I Liao, Ling-Yuan Li, Wei-Fong Kao, Ju-Sing Fan, Ying-Hsin Chen
| Article suivant Article suivant
  • Factors influencing the development of antibiotic associated diarrhea in ED patients discharged home: risk of administering IV antibiotics
  • John Patrick Haran, Gregory Hayward, Stephen Skinner, Chris Merritt, David C. Hoaglin, Patricia L. Hibberd, Shan Lu, Edward W. Boyer

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.