Abstract

Objective

Multiple reports suggest that laparoendoscopic single-site surgery is technically feasible, safe, and effective in treating a variety of gynecological disease processes. The study purpose was to assess the feasibility and safety of a novel robotic single-site platform (R-LESS) for the surgical treatment of benign and malignant gynecological conditions.

Study Design

A single-institution, prospective analysis of 40 women treated with R-LESS on the gynecology and gynecological oncology services from June 2013 through March 2014. Women undergoing hysterectomy or adnexal surgery for either a benign or malignant gynecological condition were offered robotic single-site surgery during the study period of June 1, 2013, through April 1, 2014. Patients underwent surgery through a single 2.5-3.0 cm umbilical incision with a multichannel port and utilizing the da Vinci robotic single-site platform. Two surgeons with extensive laparoendoscopic single-site experience participated.

Results

Forty patients had R-LESS performed. Procedures included total laparoscopic hysterectomy, laparoscopic supracervical hysterectomy, salpingo-oophorectomy, ovarian cystectomy, excision of endometriosis, and a combined case of total laparoscopic hysterectomy and cholecystectomy. Median age and body mass index were 42 years and 28.2 kg/m2, respectively. Median operating time, defined as the interval between incision start to closure, was 134 minutes (range, 84–311 minutes). Median vaginal cuff closure was 21 minutes (range, 9–77 minutes). Overall, there appeared to be a linear relationship between vaginal cuff closure time, console time, and operating time with number of cases performed. Procedures were successfully performed via R-LESS in 92.5% of cases; 2 cases required 1 additional port and there was 1 conversion to traditional multiport robotic surgery. There was 1 major postoperative complication (2.5%) and 1 readmission (2.5%). After a median follow-up period of 230 days (range, 61–256), there have been no postoperative hernias diagnosed.

Conclusion

We present one of the first series of robotic laparoendoscopic single-site surgery for the treatment of various gynecological conditions. When performed by experienced minimally invasive surgeons, R-LESS is feasible and safe in select patients. Further studies are needed to better define the ideal gynecological procedures to perform using robotic single-site surgery and to assess the benefits and costs of R-LESS compared with multiport robotic and conventional laparoscopic approaches.

Le texte complet de cet article est disponible en PDF.

Key words : laparoendoscopic single-site surgery, robotic surgery, single-port surgery


Plan


 The authors report no conflict of interest.
 Cite this article as: Scheib SA, Fader AN. Gynecologic robotic laparoendoscopic single-site surgery: prospective analysis of feasibility, safety, and technique. Am J Obstet Gynecol 2015;212:179.e1-8.


© 2015  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 212 - N° 2

P. 179.e1-179.e8 - février 2015 Retour au numéro
Article précédent Article précédent
  • Beyond usual care: the economic consequences of expanding treatment options in early pregnancy loss
  • Vanessa K. Dalton, Angela Liang, David W. Hutton, Melissa K. Zochowski, A. Mark Fendrick
| Article suivant Article suivant
  • Randomized controlled double-blind trial of transversus abdominis plane block versus trocar site infiltration in gynecologic laparoscopy
  • Lena El Hachem, Ethan Small, Peter Chung, Erin L. Moshier, Kathryn Friedman, Suzanne S. Fenske, Herbert F. Gretz

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.