Abbonarsi

Deep enteroscopy with a conventional colonoscope: initial multicenter study by using a through-the-scope balloon catheter system - 14/10/15

Doi : 10.1016/j.gie.2015.04.037 
Rabia Ali, MD 1, Daniel Wild, MD 2, Frederick Shieh, MD 3, David L. Diehl, MD 3, Monika Fischer, MD 4, Wataru Tamura, MD 5, David T. Rubin, MD 6, Vivek Kumbhari, MD 7, Patrick Okolo, MD 7, Andrew Storm, MD 7, Zamir Halpern, MD 8, Helmut Neumann, MD 9, Harshit S. Khara, MD 3, Mark B. Pochapin, MD 1, Seth A. Gross, MD 1,
1 New York University School of Medicine, New York, New York, USA 
2 Duke University, Durham, North Carolina, USA 
3 Geisinger Health System, Danville, Pennsylvania, USA 
4 Indiana University, Indianapolis, Indiana, USA 
5 University of Colorado, Denver, Aurora, Colorado, USA 
6 University of Chicago, Chicago, Illinois, USA 
7 Johns Hopkins Medical Institutions, Baltimore, Maryland, USA 
8 Tel Aviv Sourasky Medical Center, Tel Aviv, Israel 
9 University of Erlangen-Nuremberg, Erlangen, Germany 

Reprint requests: Seth A. Gross, MD, Division of Gastroenterology, New York University School of Medicine, 240 East 38th Street, 23rd Floor, New York, NY 10016.

Abstract

Background and Aims

The advent of capsule endoscopy has revolutionized evaluation of the small bowel. Capsule endoscopy has become the criterion standard as the initial examination to diagnose small-bowel abnormalities, but does not allow for tissue sampling or therapeutic intervention. Deep enteroscopy can be performed by using a balloon-assisted device or a spiral overtube for both diagnostic and therapeutic interventions of the small bowel. Deep enteroscopy is time-consuming and requires special endoscopes and accessories to perform the examination. We studied a novel through-the-scope balloon catheter system used for deep enteroscopy that uses a conventional colonoscope and standard accessories.

Methods

We performed a 9-center, retrospective study using a novel TTS balloon system for small-bowel evaluation. The new through-the-scope device is an on-demand balloon catheter that is inserted through the instrument channel of a standard colonoscope and enables deep advancement into the small bowel in either the anterograde or retrograde approach. It consists of a balloon inflation/deflation system and a single-use balloon catheter designed for anchoring in the small bowel. The balloon is inflated to an anchoring pressure in the small intestine, and a repetitive push-pull technique is performed, with the endoscope sliding over the guiding catheter to the inflated balloon. The catheter may be removed and reinserted to allow for therapeutic intervention while maintaining the endoscope position.

Results

A total of 98 patients were included; 52% were male, and the mean age was 55 years old (range 15-94 years). Indications included abdominal pain, iron-deficiency anemia, occult GI bleeding, diarrhea, abnormal capsule endoscopy, weight loss, protein losing enteropathy, retained foreign body, altered anatomy ERCP, and small-bowel strictures. Anterograde enteroscopy was performed in 65 patients. The average depth of insertion was 158 cm (range 50-350 cm) from the pylorus. Retrograde enteroscopy was performed in 33 cases. The average depth of insertion was 89 cm (range 20-150 cm) beyond the ileocecal valve. Overall, diagnostic yield was 44%. The average advancement time for the anterograde and retrograde enteroscopy cases was 15.5 minutes. There were no procedural adverse outcomes reported in the 98 cases.

Conclusions

The TTS advancing balloon is a safe and effective way to perform deep enteroscopy by using a conventional colonoscope without the need for an overtube. Procedure time is shorter than that of other forms of deep enteroscopy. Diagnostic yield and depth of insertion are on par with other forms of deep enteroscopy. This is the largest reported study using this novel technology to diagnose and treat small-bowel disease.

Il testo completo di questo articolo è disponibile in PDF.

Abbreviations : CE, DAE, DBE, DOI, SBE, SE, TTS


Mappa


 DISCLOSURE: Dr Halpern is a consultant for SMART Medical Systems. Dr Neumann received a SMART NaviAid system free of charge. All other authors disclosed no financial relationships relevant to this article.
 If you would like to chat with an author of this article, you may contact Dr Gross at Seth.Gross@nyumc.org.


© 2015  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 82 - N° 5

P. 855-860 - novembre 2015 Ritorno al numero
Articolo precedente Articolo precedente
  • Primum non nocere! (First do no harm!)
  • Steven A. Edmundowicz
| Articolo seguente Articolo seguente
  • Evaluation of the clinical efficacy of colon capsule endoscopy in the detection of lesions of the colon: prospective, multicenter, open study
  • Yutaka Saito, Shoichi Saito, Shiro Oka, Yasuo Kakugawa, Minori Matsumoto, Hiroyuki Aihara, Ikue Watari, Taiki Aoyama, Sadaharu Nouda, Takanori Kuramoto, Kenji Watanabe, Naoki Ohmiya, Kazuhide Higuchi, Hidemi Goto, Tetsuo Arakawa, Shinji Tanaka, Hisao Tajiri

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.