Abstract

Introduction

Cemented versions of dual-mobility cups (DMCs), helpful in cases of bone stock alteration, are usually used in association with a reinforcement device. To simplify the intervention in elderly subjects or those with a poor bone stock, the cups can be cemented directly into the bone, but the long-term result remains uncertain. We conducted a retrospective study in this population so as to: (1) assess whether cemented fixation of a DMC without a reinforcement device leads to a higher loosening rate, (2) confirm its efficacy in preventing dislocations in subjects at high risk of instability, and (3) measure the functional results.

Hypothesis

Cemented fixation of a DMC is reliable in cases of moderate alteration of bone stock.

Material and methods

Sixty-four patients (66 hips) undergoing implantation of a cemented DMC (Saturne™) without a reinforcement device were included in this single-center retrospective study. Their mean age was 79.8 years (range, 40–95 years). The indications varied: hip osteoarthritis (30.3%), prosthesis revision (44.0%), and trauma (25.8%). The patients were evaluated radiologically and clinically at follow-up. The main evaluation criterion was the revision rate for aseptic loosening. Dislocations, the infection rate, and the Postel Merle d’Aubigné (PMA) score were noted.

Results

At the mean follow-up of 4.2 years, three (4.6%) patients had been lost to follow-up and 22 (33.3%) had died. There was one case of aseptic loosening (1.5%). Cup survival was 98% at 5 years (95%CI [94–100]). There were no dislocations. There was one revision for infection. The mean PMA score was 15.5 (range, 9–18).

Discussion

The frequency of acetabular loosening was comparable to the frequency in cemented DMCs with a reinforcement device. A cemented DMC without a reinforcement device is possible and is a simple and viable option when there is moderate bone stock alteration.

Level of evidence

IV, retrospective cohort study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Hip arthroplasty, Dual mobility, Instability, Dislocation, Bone cement, Loosening


Mappa


© 2015  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 101 - N° 8

P. 923-927 - dicembre 2015 Ritorno al numero
Articolo precedente Articolo precedente
  • Proximal row carpectomy in total arthrodesis of the rheumatoid wrist
  • T.T. Pham, H. Lenoir, B. Coulet, M. Wargny, C. Lazerges, M. Chammas
| Articolo seguente Articolo seguente
  • Small diameter metal-on-metal total hip arthroplasty at 13 years – a follow-up study
  • N. Tardy, A. Maqdes, P. Boisrenoult, P. Beaufils, P. Oger

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.