Shear wave elastography: An accurate technique to stage liver fibrosis in chronic liver diseases - 09/01/16

Doi : 10.1016/j.diii.2015.11.001 
A. Guibal a, b, , G. Renosi a, A. Rode c, J.Y. Scoazec d, O. Guillaud e, L. Chardon f, M. Munteanu g, J. Dumortier e, F. Collin b, T. Lefort a
a Service de radiologie, hôpital Édouard-Herriot, hospices civils de Lyon, 69437 Lyon, France 
b Service de radiologie, centre hospitalier de Perpignan, 20, avenue du Languedoc, 66046 Perpignan cedex 9, France 
c Service de radiologie, hôpital de la Croix-Rousse, hospices civils de Lyon, 69317 Lyon, France 
d Service d’anatomo-pathologie, hôpital Édouard-Herriot, hospices civils de Lyon, 69437 Lyon, France 
e Fédération des spécialités digestives, hôpital Édouard-Herriot, hospices civils de Lyon, 69437 Lyon cedex 03, France 
f Fédération de biochimie, hôpital Édouard-Herriot, hospices civils de Lyon, 69437 Lyon, France 
g Hepatology research unit, biopredicitive, 75007 Paris, France 

Corresponding author. Service de radiologie, centre hospitalier de Perpignan, 20, avenue du Languedoc, 66046 Perpignan cedex 9, France.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Objectives

The goals of this study were to assess the diagnostic accuracy of shear wave elastography (SWE) using the results of histopathological analysis as a standard of reference and compare the results of SWE and those of transient elastography (TE) to the degree of fibrosis as evaluated by histomorphometry.

Patients and methods

Adult patients who were scheduled to undergo liver biopsy were prospectively enrolled in the study. The diagnostic performances of SWE were assessed using AUROC curve analysis according to fibrosis thresholds defined by ≥F2 (significant fibrosis), ≥F3 (advanced fibrosis) and F4 (cirrhosis). Additional analyses using the Obuchowski measures for pairwise comparisons of fibrosis stages were performed. In a subgroup of 55 patients, the relationships between stiffness as measured using SWE and TE and the percentage of fibrosis were compared using Spearman's rank coefficient.

Results

Among the initially enrolled 170 patients, 148/170 (87%) had successful SWE acquisition and formed the study population. SWE sensitivity and specificity were respectively 85.1% and 82.7% (≥F2), 88.9% and 90.3% (≥F3), 93.3% and 98.3% (F4). The AUROC curves of SWE along with their 95% confidence intervals (CI) were respectively 0.904 (95%CI: 0.845–0.946) for fibrosis ≥F2; 0.958 (95%CI: 0.912–0.984) for fibrosis ≥F3 and 0.988 (95%CI: 0.955–0.999) for fibrosis=F4. The global Obuchowski measure was 0.953±0.007. In the subgroup study, a significant correlation was found between the percentage of fibrosis and stiffness as assessed by SWE (r=0.77; 95%CI: 0.63–0.86; P<0.0001) and by TE (r=0.65; 95%CI: 0.47–0.78; P<0.01).

Conclusion

SWE is accurate to assess liver fibrosis in patients with chronic liver disease.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Elastography, Sonoelastography, Cirrhosis, Liver fibrosis, Elasticity imaging techniques

Abbreviations : SWE, TE, (w)AUROC, CI, ARFI, HBV, HCV, BMI, ROI, kPa, ICC, IQR, AST, ALT, GGT


Mappa


© 2015  Éditions françaises de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 97 - N° 1

P. 91-99 - gennaio 2016 Ritorno al numero
Articolo precedente Articolo precedente
  • Arterial splanchnic aneurysms: Presentation, treatment and outcome in 112 patients
  • R. Tétreau, H. Beji, L. Henry, P.-J. Valette, F. Pilleul
| Articolo seguente Articolo seguente
  • Uterine remnant: An uncommon finding after transvaginal hysterectomy
  • G. Ssi-Yan-Kai, E. Faivre, S. Prevot, X. Deffieux, J. De Laveaucoupet

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.