Abbonarsi

Right Bundle Branch Block-Like Pattern During Uncomplicated Right Ventricular Pacing and the Effect of Pacing Site - 26/02/16

Doi : 10.1016/j.amjcard.2015.12.028 
Stylianos Tzeis, MD a, , George Andrikopoulos, MD a, Severin Weigand, MD b, Christian Grebmer, MD b, Verena Semmler, MD b, Amir Brkic, MD b, Stefan Asbach, MD c, Axel Kloppe, MD d, Carsten Lennerz, MD b, Felix Bourier, MD b, Sokratis Pastromas, MD a, Christof Kolb, MD b
a Henry Dunant Hospital Center, Department of Cardiology, Athens, Greece 
b Deutsches Herzzentrum München, Klinik für Herz-und Kreislauferkrankungen, Abteilung für Elektrophysiologie, Faculty of Medicine, Technische Universität München, Munich, Germany 
c Department of Cardiology and Angiology I, Heart Centre Freiburg University, Freiburg, Germany 
d Berufsgenossenschaftliches Universitätsklinikum Bergmannsheil, Medizinische, Klinik II, Ruhr Universität Bochum, Bochum, Germany 

Corresponding author: Tel: (+30) 2106972000; fax: (+30) 2106972200.

Abstract

Right bundle branch block (RBBB) configuration is an unexpected finding during right ventricular (RV) pacing that raises the suspicion of inadvertent left ventricular lead positioning. The aim of this study was to evaluate the prevalence of paced RBBB pattern in relation to RV lead location. This is a secondary analysis of a prospective, multicenter study, which randomized implantable cardioverter defibrillator recipients to an apical versus midseptal defibrillator lead positioning. A 12-lead electrocardiogram was recorded during intrinsic rhythm and RV pacing. Paced RBBB–like pattern was defined as positive (>0.05 mV) net amplitude of QRS complex in leads V1 and/or V2. In total, 226 patients (65.6 ± 12.0 years, 20.8% women, 53.1% apical site) were included in the study. The prevalence of paced RBBB pattern in the total population was 15.5%. A significantly lower percentage of patients in the midseptal group demonstrated RBBB-type configuration during RV pacing compared with the apical group (1.9% vs 27.5%, p <0.001). Baseline RBBB, prolonged QRS duration during intrinsic rhythm, and reduced ejection fraction were not associated with increased likelihood of paced RBBB. In the subgroup of patients with RBBB type during pacing, 91.4% of patients had a paced QRS axis from −30° to −90°, whereas 100% of patients displayed a negative QRS vector at lead V3. In conclusion, RBBB configuration is encountered in a considerable percentage of device recipients during uncomplicated RV pacing. Midseptal lead positioning is associated with significantly lower likelihood of paced RBBB pattern compared with apical location.

Il testo completo di questo articolo è disponibile in PDF.

Mappa


 See page 939 for disclosure information.


© 2016  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 117 - N° 6

P. 935-939 - marzo 2016 Ritorno al numero
Articolo precedente Articolo precedente
  • Meta-Analysis of Efficacy and Safety of New Oral Anticoagulants Compared With Uninterrupted Vitamin K Antagonists in Patients Undergoing Catheter Ablation for Atrial Fibrillation
  • Shuang Wu, Yan-min Yang, Jun Zhu, Huai-bin Wan, Juan Wang, Han Zhang, Xing-hui Shao
| Articolo seguente Articolo seguente
  • Effect of Early Intervention With Positive Airway Pressure Therapy for Sleep Disordered Breathing on Six-Month Readmission Rates in Hospitalized Patients With Heart Failure
  • Sunil Sharma, Paul Mather, Ankit Gupta, Gordon Reeves, Sharon Rubin, Raphael Bonita, Anindita Chowdhury, Raymond Malloy, Leslee Willes, David Whellan

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.