Abbonarsi

Variation in Arterial Access for Invasive Coronary Procedures in New Zealand: A National Analysis (ANZACS-QI 5) - 31/03/16

Doi : 10.1016/j.hlc.2015.10.009 
P. Barr, BSc, MB ChB a, , D. Smyth, MBBS, MRCP, MD b, S.A. Harding, MB ChB, FRACP c, S. El-Jack, MBBS, FRACP d, M.J.A. Williams, MB ChB, Dip Obst, FRACP e, G. Devlin, MBBS, FRACP, FCSANZ f, J. Stewart, MB ChB, MD, FRCP, FRACP, FESC, FACC, FSCAI, FCSANZ g, C. Flynn, Dip Comp Nurs h, M. Lee, B Tech, MSc i, A.J. Kerr, MB ChB, FRACP f

on behalf of the ANZACS-QI investigators

a Cardiology Department, Middlemore Hospital, Auckland, NZ 
b Cardiology Department, Christchurch Hospital, Christchurch, NZ 
c School of Biological Science, Victoria University, Wellington, NZ 
d Cardiology Department, North Shore Hospital, Auckland, NZ 
e Department of Medicine, Dunedin School of Medicine, University of Otago, Dunedin, NZ 
f Medicine, University of Auckland, Auckland, NZ 
g Cardiology Department, Auckland City Hospital, Auckland, NZ 
h Counties Manukau District Health Board, Auckland, New Zealand 
i Counties Manukau District Health Board, Auckland, New Zealand 

Corresponding author at: Department of Cardiology, Middlemore Hospital, Otahuhu, Auckland 93311, New Zealand.

Riassunto

Background

Radial arterial access (RA) and femoral arterial access (FA) rates for invasive coronary angiography (ICA) vary widely internationally. The European Society of Cardiology (ESC) suggests default RA is feasible. We aim to investigate the variation in RA rates across all New Zealand public hospitals.

Methods and Results

Patient characteristics, procedural details, and inpatient outcome data were collected in the All New Zealand Acute Coronary Syndrome – Quality Improvement (ANZACS-QI) registry on consecutive patients undergoing ICA over five months. Of the 5894 ICAs 81% were via RA. Hospitals averaged 25 – 176 procedures/month (46.5% – 96.4% via RA). Operators averaged 17 procedures/month. Those performing more than 20 ICAs/month had RA rates between 61% – 99%. Of the 75 operators, 69% met the ESC recommendation. After multivariable adjustment higher operator (RR 1.12, CI 1.09 – 1.30) and hospital (RR 1.21, CI 1.15 – 1.28) volume were independent predictors of RA. Those with prior CABG (RR 0.51, CI 0.45 – 0.57), STEMI <12h (RR 0.91, CI 0.87 – 0.96), and female sex (RR 0.96, CI 0.94 – 0.99) were less likely to receive RA.

Conclusions

New Zealand has a high RA rate for ICAs. Rates vary substantially between both operators and centres. Radial arterial was highest amongst the highest volume operators and centres.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Access site, Radial artery catheter, Cardiac catheterisation.


Mappa


© 2015  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 25 - N° 5

P. 451-458 - maggio 2016 Ritorno al numero
Articolo precedente Articolo precedente
  • The Management of Supraventricular Tachyarrhythmias in Patients with Pulmonary Arterial Hypertension
  • Katarzyna Ma?aczy?ska-Rajpold, Anna Komosa, Krzysztof B?aszyk, Aleksander Araszkiewicz, Magdalena Janus, Anna Olasi?ska-Wi?niewska, Stanis?aw Jankiewicz, Maciej M?czy?ski, Tatiana Mularek-Kubzdela
| Articolo seguente Articolo seguente
  • Effects of Combination of Ezetimibe and Rosuvastatin on Coronary Artery Plaque in Patients with Coronary Heart Disease
  • Xiaofang Wang, Xiaoyan Zhao, Ling Li, Haimu Yao, Yan Jiang, Jinying Zhang

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.