Abbonarsi

Electroanatomic Mapping and Transoesophageal Echocardiography for near Zero Fluoroscopy during Complex Left Atrial Ablation - 28/05/16

Doi : 10.1016/j.hlc.2016.01.018 
Hariharan Raju, MBChB, MRCP, PhD , John Whitaker, BMBCh, MRCP, Carly Taylor, BSc, Matthew Wright, MBBS, MRCP, PhD, FHRS
 Cardiology Department, St Thomas’ Hospital, London, UK 

Corresponding author at: Cardiac Electrophysiology Fellow / Registrar, Cardiology, East Wing Level 6, St Thomas’ Hospital, London SE1 7EH, United Kingdom. Tel.: +44 (0)207 1887335; fax: +44 (0)2071881011

Riassunto

Background

We evaluated Carto 3, transoesophageal echocardiography (TOE) and contact force (CF) sensing catheter in atrial fibrillation (AF) ablation.

Methods

Unselected consecutive ablations performed under general anaesthesia (GA) were studied with modified protocol (cases, n=11) and compared to retrospective consecutive controls (n=10). Patent foramen ovale (PFO) or single transseptal puncture enabled left atrial (LA) access; ablation strategy was stepwise approach. Modified protocol utilised right atrial (RA) electrograms, CF and TOE to localise SmartTouch and create RA and CS electroanatomic map (EAM) without fluoroscopy. Transseptal puncture was performed with fluoroscopy in absence of PFO. Fluoroless pulmonary vein and LA EAM was created using TOE to locate circular-mapping catheter.

Results

Mean age of cases was 57±11 years with 64% male compared with 60±11 (70% male) for controls. Patent foramen ovale was identified in four cases (36%) and two controls (20%). No early complications occurred. Shorter fluoroscopy time (median 36 vs 390seconds; p=0.038) and trend to lower radiation dose (median 17 vs 165 cGym2; p=0.053) was seen in cases, with no increase in total procedure time (p=0.438).

Conclusions

General anaesthesia, TOE and CF mapping catheters facilitate minimised fluoroscopy for catheter ablation of LA arrhythmias. Zero fluoroscopy is possible in a majority of cases with PFO.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Fluoroscopy, Radiation dosage, Catheter ablation, Atrial fibrillation, Foramen ovale, Patent


Mappa


© 2016  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 25 - N° 7

P. 652-660 - luglio 2016 Ritorno al numero
Articolo precedente Articolo precedente
  • Persistent Atrial Fibrillation Ablation using the Tip-Versatile Ablation Catheter
  • Edward J. Davies, Ben Clayton, Ian Lines, Guy A. Haywood
| Articolo seguente Articolo seguente
  • Transcatheter versus Surgical Aortic Valve Replacement in High-risk Patients: A propensity-score matched analysis
  • India Zweng, William Y. Shi, Sonny Palmer, Andrew MacIsaac, Robert Whitbourn, Philip Davis, Andrew E. Newcomb

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.