Abbonarsi

Is anterior glenoid bone block position reliably assessed by standard radiography? A cadaver study - 09/11/16

Doi : 10.1016/j.otsr.2016.08.005 
P. Clavert a, b, , G. Koch a, L. Neyton c, P. Metais d, J. Barth e, G. Walch c, L. Lafosse f
the

French Arthroscopic Society

a Institut d’anatomie normale, FMTS, faculté de médecine, 4, rue Kirschleger, 67085 Strasbourg cedex, France 
b Service de chirurgie du membre supérieur, CCOM, avenue Baumann, 67400 Illkirch, France 
c Centre orthopédique Santy, hôpital privé J.-Mermoz (Ramsay-GDS), 24, avenue Paul-Santy, 69008 Lyon, France 
d Clinique La Châtaigneraie, 63110 Beaumont, France 
e Centre ostéo-articulaire des Cèdres, parc Sud Galaxie, 5, rue des Tropiques, 38130 Échirolles, France 
f Clinique générale d’Annecy, 74000 Annecy, France 

Corresponding author. Laboratoire ICube–UMR 7357, institut d’anatomie normale, faculté de médecine, 4, rue Kirschleger, 67085 Strasbourg cedex, France.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background

Standard radiography with an antero-posterior view and Bernageau's glenoid profile view is the method most widely reported in the literature to assess coracoid bone block position and fusion.

Objective

The aim of this cadaver study was to determine whether the antero-posterior and Bernageau's radiographs provide a reliable and reproducible evaluation of the position of a coracoid bone block and its fixation screws.

Method

An isolated scapula showing no evidence of osteoarthritis or other abnormalities was used. The coracoid process was transferred to the anterior glenoid rim. Fixation was with two slightly diverging malleolar screws, chosen of different sizes for ease of identification. Computed tomography (CT) was performed as the reference imaging technique. The standard radiographs were then obtained, using fluoroscopy to accurately position the scapula for the antero-posterior and Bernageau's views. This position was defined as 0°, and radiographs were taken at angles of 5°, 10°, and 15° in all three planes. All radiographs were taken during a single session to ensure that the distance separating the tube from the scapula remained unchanged. The images were exported to OsiriX for analysis. We measured the angles formed by the screws and the glenoid surface, as well as bone block position and overhang. Finally, we used 1-mm thick disks to evaluate bone-to-bone contact.

Results

No correlations were found between values by CT and by standard radiography (both views) for the screw angles or overhang. A space1mm between the neck of the scapula and the bone block was not visible on the standard radiographs in any of the positions.

Conclusion

Standard radiography does not provide an accurate analysis of bone block position or bone-to-bone contact. CT is needed to assess bone block and screw position and bone-to-bone contact.

Level of evidence

Level III.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Imaging, Scapula, Coracoid transfer, Position, Fusion, Bernageau


Mappa


© 2016  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 102 - N° 8S

P. S281-S285 - dicembre 2016 Ritorno al numero
Articolo precedente Articolo precedente
  • Functional outcomes after open versus arthroscopic Latarjet procedure: A prospective comparative study
  • G. Nourissat, L. Neyton, P. Metais, P. Clavert, B. Villain, D. Haeni, G. Walch, L. Lafosse, the French Arthroscopic Society
| Articolo seguente Articolo seguente
  • Complications in posteromedial arthroscopic suture of the medial meniscus
  • N. Jan, B. Sonnery-Cottet, J.-M. Fayard, C. Kajetanek, M. Thaunat

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2025 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.