Background

Despite excellent long-term outcomes, posterior stabilisation by a third condyle continues to receive unwarranted criticism regarding patellar complications and instability.

Hypothesis

Complication rates with a tri-condylar posterior-stabilised implant are similar to those with other posterior-stabilised prostheses and have diminished over time due to improvements in prosthesis design.

Material and methods

Post-operative complications and revision rates were assessed retrospectively in a prospective cohort of 4189 consecutive patients who had primary total knee arthroplasty (TKA) using a tri-condylar posterior-stabilised implant (Wright-Tornier) and were then followed-up for at least 24 months. The analysis included 2844 knees. The prosthesis generations were HLS1®, n=20; HLS2®, n=220; HLS Evolution®, n=636; HLS Noetos®, n=1373; and HLS KneeTec®, n=595. Complications were compared across generations by applying Fisher's exact test, and survival was compared using the Kaplan-Meier method.

Results

At last follow-up, there had been 341 (12%) post-operative complications in 306 (10.8%) knees, including 168 (5.9%) related to the implant, 41 (1.4%) infections, and 132 (4.6%) secondary complications unrelated to the implant. Re-operation was required for 200 complications (7%), including 87 (3.1%) consisting in revision of the prosthesis. Implant-related complications were stiffness (n=67, 2.4%), patellar fracture (n=34, 1.2%), patellar clunk syndrome (n=25, 0.9%), patellar loosening (n=3, 0.1%), tibial/femoral loosening (n=15, 0.5%), polyethylene wear (n=3, 0.1%), and implant rupture (n=1, 0.04%). Significant differences across generations were found for stiffness (P<0.0001), patellar fracture (P=0.03), clunk syndrome (P=0.03), and polyethylene wear (P=0.004), whose frequencies declined from one generation to the next. Overall 10-year survival was 92% with no significant difference across generations (P=0.1).

Discussion

Outcomes of tri-condylar posterior-stabilised TKA are similar to those obtained using other posterior-stabilised implants. Neither patellar complications nor instability are more common, and improvements in implant design have contributed to correct early flaws.

Level of evidence

IV, historical cohort, retrospective assessment of prospectively collected data.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Total knee arthroplasty, Complications, Posterior stabilisation, Third midline condyle, Implant design


Mappa


© 2016  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 102 - N° 8

P. 1061-1068 - dicembre 2016 Ritorno al numero
Articolo precedente Articolo precedente
  • Validation of a French patient-reported outcome measure for patello-femoral disorders: The Lille Patello-Femoral Score
  • S. Putman, F. Rémy, G. Pasquier, F. Gougeon, H. Migaud, A. Duhamel
| Articolo seguente Articolo seguente
  • Tibiofemoral syndesmosis injury treated by temporary screw fixation and ligament repair
  • S. Steinmetz, B. Puliero, D. Brinkert, N. Meyer, P. Adam, F. Bonnomet, M. Ehlinger

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.