Abbonarsi

Unenhanced respiratory-navigated NATIVE® TrueFISP magnetic resonance angiography in the evaluation of renal arteries: Comparison with contrast-enhanced magnetic resonance angiography - 01/02/17

Doi : 10.1016/j.diii.2016.06.013 
B. Değirmenci a, , M. Kara a, V. Kıdır b, S. İnal c, T. Sezer c, A. Umul a, H. Orhan d, A.O. Çelik a, H. Demirtaş a, Ö. Yilmaz a
a Department of radiology, school of medicine, Süleyman Demirel university, 32260 Isparta, Turkey 
b Department of nephrology, Dumlupınar university, Kütahya Evliya Celebi training and research hospital, Kütahya, Turkey 
c Department of nephrology, school of medicine, Süleyman Demirel university, Isparta, Turkey 
d Department of biostatistics, school of medicine, Süleyman Demirel university, Isparta, Turkey 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Purpose

To compare unenhanced three-dimensional (3D) NATIVE® true fast imaging with steady-state precession (TrueFISP) magnetic resonance (MR) angiography with the more conventional MR angiography technique obtained after intravenous administration of a gadolinium chelate in the evaluation of renal arteries and their branches in patients with suspected renal artery stenosis.

Materials and methods

A total of 39 patients (25 men, 14 women) with a mean age of 51.4±17.5years (SD) (range: 10–82years) were included in the study. All patients with suspected renal artery stenosis underwent unenhanced 3D NATIVE® TrueFISP MR angiography and contrast-enhanced MR angiography. The two MR angiography methods were compared by two independent readers for image quality using a four-point scale, diagnostic performance and grading of renal artery stenosis on a total of 78 renal arteries.

Results

For both readers image quality of unenhanced 3D NATIVE® TrueFISP MR angiography (3.12 to 3.63) was greater than that of contrast-enhanced MR angiography (1.94 to 2.71) for renal artery ostium-trunk and the left renal artery segmental branches. The sensitivity of 3D NATIVE® TrueFISP MR angiography for the diagnosis of renal artery stenosis was 100% for both readers for the right renal artery and 66% and 80% for the left renal artery for reader 1 and reader 2, respectively. Agreement between 3D NATIVE® TrueFISP MR angiography and CE-MR angiography was 95% (74/78) for reader 1 and 92% (72/78) for reader 2.

Conclusion

Unenhanced NATIVE® TrueFISP magnetic resonance angiography can play an additional role in the evaluation of renal arteries in patients with hypertension, especially in subjects at risk of nephrogenic systemic fibrosis.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : MR angiography, MR imaging, Technique, Renal artery, Arterial hypertension

Abbreviations : RAS, CE-MRA, TOF, PC, SSFP, 3D, TrueFISP, TI, VR, MIP, FOV


Mappa


© 2016  Éditions françaises de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 98 - N° 2

P. 133-140 - Febbraio 2017 Ritorno al numero
Articolo precedente Articolo precedente
  • Usefulness of T2 ratio in the diagnosis and prognosis of cardiac amyloidosis using cardiac MR imaging
  • F. Legou, V. Tacher, T. Damy, V. Planté-Bordeneuve, S. Rappeneau, N. Benhaiem, J. Rosso, E. Itti, A. Luciani, H. Kobeiter, A. Rahmouni, J.-F. Deux
| Articolo seguente Articolo seguente
  • Pancreas divisum: A risk factor for pancreaticobiliary tumors – an analysis of 1628 MR cholangiography examinations
  • Z.H. Adibelli, M. Adatepe, L. Isayeva, O.S. Esen, M. Yildirim

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2024 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.