Abbonarsi

Evaluating augmentation with calcium phosphate cement (chronOS Inject) for bone defects after internal fixation of proximal tibial fractures: A prospective, multicenter, observational study - 08/02/17

Doi : 10.1016/j.otsr.2016.10.006 
C.W. Oh a , K.C. Park b, , Y.H. Jo b
a Department of Orthopedic Surgery, Kyungpook National University Hospital, 130 Dongduk-ro, Jung-gu, Daegu 41944, Republic of Korea 
b Department of Orthopedic Surgery, Hanyang University Guri Hospital, 153 Kyoungchun-ro, Guri-si, Gyeonggi-do 11923, Republic of Korea 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Introduction

Managing subchondral bone defects in proximal tibia fractures after plateau reduction is an important consideration. ChronOS Inject is a recently developed calcium phosphate bone substitute that shows relatively fast osteointegration.

Hypothesis

Using chronOS Inject during internal fixation of proximal tibial fractures provides a satisfactory treatment option that is both clinically and radiologically safe.

Patients and methods

Patients enrolled in this study were treated with chronOS Inject bone void filler, during internal fixation of proximal tibial fractures. Patients were evaluated preoperatively and at 6 weeks, 6 and 12 months postoperative. Radiographic union was assessed using plain films supplemented by CT scans. Pain, function and adverse events were collected at all visits. A total of 36 patients were enrolled in the study and treated according to a predetermined protocol. Seven of the 36 patients (19.4%) were lost to follow-up.

Results

Successful radiographic union was achieved in 27/29 (93.1%) of patients at final follow-up. Articular subsidence of>2mm only occurred in one patient. Statistical analysis showed significant improvements both in leg pain and knee function. Progress in knee function was observed in 93.1% (27/29) of patients from 6 weeks to 12 months. No product-related complications were reported.

Conclusions

Successful union was achieved based on radiographic criteria as well as clinical outcomes. When managing bone defects after internal fixation of proximal tibial fractures, the use of chronOS Inject resulted in significant improvement of knee function and reduction of leg pain.

Level of evidence

Level IV, prospective observational study.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Proximal tibial fractures, Bone defect, Calcium phosphate cement


Mappa


© 2016  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 103 - N° 1

P. 105-109 - febbraio 2017 Ritorno al numero
Articolo precedente Articolo precedente
  • Concurrent carpal tunnel syndrome and pronator syndrome: A retrospective study of 21 cases
  • C.-W. Hsiao, J.-T. Shih, S.-T. Hung
| Articolo seguente Articolo seguente
  • Does weight-bearing assignment after intramedullary nail placement alter healing of tibial shaft fractures?
  • D.A. Greenhill, M. Poorman, C. Pinkowski, F.V. Ramsey, C. Haydel

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.