Purpose

Scaphoid fracture commonly occurs around the mid-third of the scaphoid, and non-union of this fracture has several treatment options. The authors performed autologous cancellous bone graft from the iliac crest and headless compression screw fixation for the treatment of Mack-Lichtman type II scaphoid waist non-union. The purpose of this study was to determine whether this procedure was effective in achieving bony union and restoration of alignment.

Methods

Medical records and radiographs of 30 patients who underwent cancellous bone graft and headless compression screw fixation for non-union of scaphoid waist fracture were retrospectively reviewed. There were 28 men and 2 women, with a mean age of 32.8 years (range: 21–63). The mean time to surgery was 10 months (range: 3–25) and mean follow-up was 37.5 months (range: 15–52). The authors analyzed bony union, lateral intrascaphoid angle, scapholunate angle, radiolunate angle and scaphoid length on radiographs and evaluated the Modified Mayo wrist score (MMWS) as a functional outcome.

Results

Bony union was achieved in all cases. The lateral intrascaphoid angle improved from 40° to 32° (P<0.001). The scapholunate angle also improved from 61° to 56° (P=0.009). The radiolunate angle decreased from 8° to 4° (P=0.048) and scaphoid length increased from 22mm to 26mm (P<0.001) postoperatively. Wrist motion and MMWS improved significantly at last follow-up. However, there were no significant differences between scaphoid deformity correction angle and pre- to post-operative difference in MMWS.

Conclusions

Non-structural autologous cancellous bone graft from the iliac crest and headless screw fixation provided reliable results and can be one of the effective treatment options for patients with symptomatic Mack-Lichtman type II non-union in the mid-third of the scaphoid.

Level of evidence

Level III.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Cancellous bone graft, Headless compression screw, Non-union, Scaphoid


Mappa


© 2016  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 103 - N° 1

P. 89-93 - febbraio 2017 Ritorno al numero
Articolo precedente Articolo precedente
  • Minimally invasive hardware removal after minimally invasive distal radius plate osteosynthesis (MIPO): Feasibility study in a 388 case series
  • P. Luigi Medda, A.-S. Matheron, J.J. Hidalgo Diaz, N. Maire, P. Vernet, S. Facca, P. Liverneaux
| Articolo seguente Articolo seguente
  • Treatment of acute perilunate dislocations: ORIF versus proximal row carpectomy
  • T. Muller, J.J. Hidalgo Diaz, E. Pire, G. Prunières, S. Facca, P. Liverneaux

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.