Abbonarsi

Endoscopic slip-knot clip suturing method: prospective pilot study (with video) - 20/04/17

Doi : 10.1016/j.gie.2016.07.047 
Toshihiro Nishizawa, MD, PhD 1, 2, , Yasutoshi Ochiai, MD, PhD 1, Toshio Uraoka, MD, PhD 1, 3, Teppei Akimoto, MD 1, Yutaka Mitsunaga, MD 1, Osamu Goto, MD, PhD 1, Ai Fujimoto, MD, PhD 1, Tadateru Maehata, MD, PhD 1, Takanori Kanai, MD, PhD 2, Naohisa Yahagi, MD, PhD 1
1 Division of Research and Development for Minimally Invasive Treatment, Cancer Center, Keio University School of Medicine, Tokyo, Japan 
2 Division of Gastroenterology and Hepatology, Department of Internal Medicine, Keio University School of Medicine, Tokyo, Japan 
3 Division of Gastroenterology, National Hospital Organization Tokyo Medical Center, Tokyo, Japan 

Reprint requests: Toshihiro Nishizawa, MD, PhD, Division of Gastroenterology and Hepatology, Department of Internal Medicine, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo 160-8582, Japan.Division of Gastroenterology and HepatologyDepartment of Internal MedicineKeio University School of Medicine35 ShinanomachiShinjuku-kuTokyo 160-8582Japan

Abstract

Background and Aims

We developed a suturing method with a slip-knot string and clips for a single-channel endoscope. The feasibility of the slip-knot clip suturing method was evaluated in this clinical pilot study.

Methods

Ten patients underwent endoscopic submucosal dissection for colorectal and duodenal tumors 5 cm or less. A slip-knot loop can be tightened when tension is applied to the free end of the string. A clip and string can be passed through an instrument channel (3.2 mm) of a single-channel endoscope. The slip-knot loop is anchored onto the mucosal defect’s proximal margin with the clip. Additional clips anchoring the slip-knot loop are placed at the opposite side of the margin. The slip-knot loop is tightened by pulling the string. Additional clips are placed to achieve complete closure.

Results

The mean size of resected specimen was 34.4 ± 10.0 mm. The success rate of the slip-knot clip suturing method was 90% (9/10). In the first patient, the string was cut because of friction, and the patient dropped out of the study. After the failure of the first patient, we used wet string to reduce friction, and slip-knot string worked effectively. The mean procedure time was 18.2 ± 3.3 minutes.

Conclusion

The slip-knot clip suturing method could close large mucosal defects completely using a single-channel endoscope. (Clinical trial registration number: UMIN000017583.)

Il testo completo di questo articolo è disponibile in PDF.

Abbreviation : ESD


Mappa


 DISCLOSURE: All authors disclosed no financial relationships relevant to this publication.
 If you would like to chat with an author of this article, you may contact Dr Nishizawa at nisizawa@kf7.so-net.ne.jp.


© 2017  American Society for Gastrointestinal Endoscopy. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 85 - N° 2

P. 433-437 - febbraio 2017 Ritorno al numero
Articolo precedente Articolo precedente
  • Biliary bypass redux: lessons for the therapeutic endoscopist from the archives of surgery
  • Eduardo Rodrigues-Pinto, Ian S. Grimm, Todd H. Baron
| Articolo seguente Articolo seguente
  • Maneuverability and safety of a magnetic-controlled capsule endoscopy system to examine the human colon under real-time monitoring by colonoscopy: a pilot study (with video)
  • Hongxiang Gu, Huiling Zheng, Xiaobing Cui, Ying Huang, Bo Jiang

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.