Abbonarsi

Acetate templating on calibrated standing digital radiograph improves accuracy of preoperative templating for total hip arthroplasty - 21/04/17

Doi : 10.1016/j.otsr.2016.12.022 
Q. Wang a, 1, J. Xiao b, 1, L. Zhu c, X. Zhao a, Z. Liu a, J. Wang a, Y. Qin a,
a Department of Orthopaedic Surgery, 2nd Hospital of Jilin University, 218#, Zi Qiang Street, Changchun, Jilin, 130041, China 
b Department of Orthopaedic Surgery, China-Japan Union Hospital of Jilin University, 126#, Xian Tai Street, Changchun, Jilin, 130033, China 
c Changchun University of Chinese Medicine, 1035#, Bo Shuo Street, Changchun, Jilin, 130000, China 

Corresponding author. Department of Orthopaedic Surgery, 2nd Hospital of Jilin University, No. 18, Ziqiang street, Nanguan District, Changchun 130041, China.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Background

The accuracy of preoperative templating with respect to leg length, femoral offset, and the size of femoral and acetabular components is essential to the success of total hip arthroplasty (THA). Traditionally, templating has been performed using printed film with acetate templates. However, preoperative templating designed by different prosthetic manufacturers cannot be used directly on the film due to varying acetate template amplification ratios. Computer-based templating needs specialized digital templating software, which has cost implications. To address these shortcomings, we bring forward several questions: (1) the accuracy of traditional manual templating combined with the calibrated digital radiograph for preoperative templating, (2) the inter- and intraobserver reliability of this method.

Hypothesis

Using calibrated digital radiograph with traditional manual templating improves the accuracy and reproducibility of preoperative templating for THA.

Patients and methods

We designed a stepwise method that combines the traditional manual templating with standing digital radiograph calibrated by a scaling ball. Two separate observers (XJL, QYG) analyzed data of 82 patients (109 THAs) who had undergone THA with preoperative templating using the calibrated digital templating. The intra- and interobserver reliability was assessed by intraclass correlation coefficient.

Results

The size of the acetate template acetabular based on our method was identical to the actual implanted acetabular size in 55.0% (XJL 110/218 [50.5%]; QYG 130/218 [59.6%]) of the cases indicating moderate accuracy. The intraclass correlation coefficient (ICC) for acetabular templating indicated almost perfect interobserver (ICC=0.918 [95% CI, 0.893–0.937]) and intraobserver agreement (ICC=0.932 [95% CI, 0.912–0.947]). While the exact implanted femoral size was predicted in 55.3% (XJL 122/218 [56.0%]; QYG 119/218 [54.6%]) of the cases. The ICC for femoral component templating indicated almost perfect interobserver (ICC=0.944 [95% CI, 0.927–0.957]) and intraobserver agreement (ICC=0.909 [95% CI, 0.883–0.930]).

Discussion

This new stepwise method may prove to be a more reliable preoperative design choice to accurately calibrate magnification with radiograph, and could solve the incompatibility of the preoperative template designed by different prosthetic companies for direct use with the x-ray film. The method described is practical, convenient, cost-effective and does not require specialized equipment or software, thus making it particularly suitable for use in underdeveloped settings.

Level of evidence

Level IV, case series without controls.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Calibration, Standing digital radiograph, Templating, THA


Mappa


© 2017  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 103 - N° 3

P. 341-347 - maggio 2017 Ritorno al numero
Articolo precedente Articolo precedente
  • Epidemiology and treatment of acetabular fractures in a level-1 trauma centre: Retrospective study of 414 patients over 10 years
  • M. Boudissa, F. Francony, G. Kerschbaumer, S. Ruatti, M. Milaire, P. Merloz, J. Tonetti
| Articolo seguente Articolo seguente
  • Is there a role for femoral offset restoration during total hip arthroplasty? A systematic review
  • M. De Fine, M. Romagnoli, A. Toscano, A. Bondi, M. Nanni, S. Zaffagnini

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.