Abstract

Purpose

The aim of this study was to assess the performances of unenhanced post-mortem computed tomography (CT) to detect thoracic injuries in violent death.

Materials and methods

Retrospectively, we conducted a review of unenhanced CT scans of 67 victims of violent deaths with thoracic injuries and compared CT findings with the results of clinical autopsy. Our gold standard was a comparison of CT scans with autopsy discussed in a monthly forensic radiology multidisciplinary team meeting (MDTM). The data were collected by organ system: heart, pericardium, aorta, lungs, pleura, bone, and diaphragm and performance indices (sensitivity, specificity, accuracy) were calculated.

Results

Pleural (59/67) and bone (55/67) injuries detected on CT were also found at autopsy and confirmed by the MDTM (sensitivity and specificity 100%). Seventeen out of 67 diaphragmatic lesions were visible on CT. Eighteen out of 67 were confirmed during MDTM after autopsy, yielding overall sensitivity of 94% and specificity of 98%. Forty out of 67 lung contusions were found on CT with two false positives and one false negative yielding 95% sensitivity for CT with a specificity of 96%, and accuracy of 95%. Fourteen out of 67 aortic injuries were found on CT compared to 19 confirmed during MDTM (sensitivity 74%, specificity 85%, accuracy 82%). In terms of pericardial lesions, 19/67 were found on CT and 20 on autopsy and confirmed during MDTM (sensitivity 80%, specificity 94%, accuracy 85%). Ten out of 10/67 cardiac lesions were visible on CT imaging and 15 found on autopsy and confirmed during MDTM (sensitivity 57%, specificity 94%, accuracy 81%).

Conclusion

Unenhanced post-mortem CT performs well to detect pleural, pulmonary, bone and diaphragmatic injuries but less well to identify cardiac and aortic injuries, for which the use of indirect signs is essential.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Post-mortem CT scan, Autopsy, Thorax, Violent death


Mappa


© 2016  Éditions françaises de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 98 - N° 5

P. 393-400 - maggio 2017 Ritorno al numero
Articolo precedente Articolo precedente
  • Diagnosis of hepatocellular carcinoma: An update on international guidelines
  • C. Cassinotto, C. Aubé, A. Dohan
| Articolo seguente Articolo seguente
  • Added value of diffusion-weighted magnetic resonance imaging for the diagnosis of perianal fistula
  • M. Cavusoglu, S. Duran, D. Sözmen C?l?z, G. Tufan, H.G. Hatipoglu Çetin, A. Ozsoy, B. Sakman

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.