Abbonarsi

Exploring the best predictors of fluid responsiveness in patients with septic shock - 21/08/17

Doi : 10.1016/j.ajem.2017.03.052 
Nianfang Lu a, Xiuming Xi a, , Li Jiang a, Degang Yang b, Kai Yin c
a Department of Critical Care Medicine, Fuxing Hospital, Capital Medical University, Beijing 100038, China 
b Department of Spinal and Neural Functional Reconstruction, China Rehabilitation Research Center, School of Rehabilitation Medicine, Capital Medical University, Beijing 100068, China 
c Department of Critical Care Medicine, Beijing Electric Power Hospital, Beijing 100073, China 

Corresponding author.

Abstract

Objective

To evaluate respiratory variations in carotid and brachial peak velocity and other hemodynamic parameters to predict responsiveness to fluid challenge.

Methods

A prospective observational study was performed on mechanically ventilated patients with septic shock. Outcomes included the measurements of central venous pressure, intrathoracic blood volume index, stroke volume variation (SVV), pleth variability index(PVI), and ultrasound assessments of respiratory variations in inferior vena cava diameter (ΔIVC), carotid Doppler peak velocity (ΔCDPV), and brachial artery peak velocity (ΔVpeak brach).

Results

All patients received 200 mL normal saline challenge. There were 27 responders and 22 non-responders. Responders had higher SVV, PVI, ΔIVC, ΔCDPV, and ΔVpeak brach measurements. In addition, all these measurements had statistically significant linear correlations with changes in cardiac index (CI).When responders were defined by ΔCI10%, receiver operating characteristics (ROC) curve analysis showed that fluid responsiveness could be predicted:11.5% optimal cut-off 1evels of SVV with sensitivity of 75% and specificity of 85%, 15.5% optimal cut-off 1evels of PVI with sensitivity of 65% and specificity of 80%, 20.5% optimal cut-off 1evels of ΔIVC with sensitivity of 67% and specificity of 77%, 13% optimal cut-off 1evels of ΔCDPV with sensitivity of 78%% and specificity of 90%, 11.7% optimal cut-off 1evels of ΔVpeak brach with sensitivity of 70% and specificity of 80%.

Conclusion

Ultrasound assessment of ΔIVC and ΔVpeak brach, especially ΔCDPV, could predict fluid responsiveness and might be recommended as a continuous and noninvasive method to monitor functional hemodynamic parameter in mechanically ventilated patients with septic shock.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Septic shock, Ventilation, Doppler ultrasound, Inferior vena cava diameter, Carotid Doppler peak velocity, Brachial artery peak velocity


Mappa


© 2017  Elsevier Inc. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 35 - N° 9

P. 1258-1261 - settembre 2017 Ritorno al numero
Articolo precedente Articolo precedente
  • Factors associated with hospital admission after an emergency department treat and release visit for older adults with injuries
  • Emily C. Earl-Royal, Elinore J. Kaufman, Alexandra L. Hanlon, Daniel N. Holena, Kristin L. Rising, M. Kit Delgado
| Articolo seguente Articolo seguente
  • Retrospective comparison of the Low Risk Ankle Rules and the Ottawa Ankle Rules in a pediatric population
  • Amy L. Ellenbogen, Amy L. Rice, Pranav Vyas

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.