Abbonarsi

Supplement CT-Guided Microcoil Placement for Localising Ground-glass Opacity (GGO) Lesions at “Blind Areas” of the Conventional Hook-Wire Technique - 27/09/17

Doi : 10.1016/j.hlc.2016.10.004 
Tao Zuo, MD a, 1, Shunbin Shi, MD b, 1, Long Wang, MD c, 1, Zhe Shi, MD c, Chenyang Dai, MD c, Chuanyi Li, MD c, Xiaogang Zhao, MD c, Zhengyi Ni, MD a, Ke Fei, MD c, Chang Chen, MD c,
a Department of Thoracic Surgery, Wuhan Medical Treatment Center, Shanghai, China 
b Department of Thoracic Surgery, First People's Hospital of Wujiang, Medical School of Nantong University, Shanghai, China 
c Department of Thoracic Surgery, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, China 

Corresponding author at: Department of Thoracic Surgery, Shanghai Pulmonary Hospital, Tongji University School of Medicine, Shanghai, China. Tel.: +021-65115006

Riassunto

Background

In the conventional hook-wire technique of pulmonary nodular localisations there are several “blind areas”, including the mediastinum-vicinity region, interlobar fissure-neighbouring areas and scapulae-shadowed areas. The present study aims to summarise the experiences of CT-guided microcoil placement as an alternative method for localising pulmonary ground-glass opacity (GGO) lesions before thoracoscopic wedge resections.

Methods

Sixteen GGO lesions at “blind areas” in 16 patients were localised with platinum-fibered microcoils under CT assistance before undergoing video-assisted thoracoscopic surgical resections. Information regarding coil placement, operations and complications was recorded.

Results

Of all lesions, 1 was in the mediastinum-vicinity region, 8 were covered by the scapulae, and 7 were close to interlobar fissures (3 horizontal fissures, 4 oblique fissures). All 16 (100%) lesions had been successfully marked with microcoils. No major complications of the puncture procedure occurred; there were only minor pneumothorax (n=2) and haemoptysis (n=1) complications, which required no intervention before operations. All GGO lesions and microcoils were successfully removed by initial wedge resections. Of the 16 lesions in “blind areas”, 8 were adenocarcinoma in situ (AIS), 4 were minimally invasive adenocarcinoma (MIA), 3 were atypical adenomatous hyperplasia (AAH), and 1 was interstitial fibrous tissue proliferation. No major complications occurred postoperatively.

Conclusions

For the “blind areas” of the hook-wire technique, CT-guided microcoil placement is an effective method of marking GGO lesions that makes thoracoscopic wedge resection easier.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Lung cancer surgery, Thoracoscopy/VATS


Mappa


© 2016  Pubblicato da Elsevier Masson SAS.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 26 - N° 7

P. 696-701 - luglio 2017 Ritorno al numero
Articolo precedente Articolo precedente
  • Transcatheter Closure of Perimembranous Ventricular Septal Defects Using Dual Wire-Maintaining Technique
  • Xu-Dong Xu, Li-Ming Gao, Yuan Bai, Zhi-Gang Zhang, Xiao-Hua You, Xian-Xian Zhao, Yong-Wen Qin
| Articolo seguente Articolo seguente
  • The Effect of Left Ventricular Assist Device Implantation on Serum Albumin, Total Protein and Body Mass: A Short-Term, Longitudinal Follow-Up Study
  • Tolga Sinan Guvenc, Ozge Güzelburc, Ahmet Ekmekci, Sevinc Bayer Erdogan, Rengin Cetin Guvenc, Yalcin Velibey, Muge Tasdemir, Semra Agustos, Gokcen Orhan, Serap Aykut Aka, Mehmet Eren

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.