Abbonarsi

The kinematic alignment technique for TKA reliably aligns the femoral component with the cylindrical axis - 07/11/17

Doi : 10.1016/j.otsr.2017.06.016 
C. Rivière a, , F. Iranpour a, S. Harris a, E. Auvinet a, A. Aframian a, P. Chabrand b, J. Cobb a
a Department of joint replacement, the MSK Lab, Charing Cross Campus, Laboratory Block, Fulham Palace Rd, W6 8RP London, UK 
b Institut des sciences du mouvement, université Aix-Marseille, 171, avenue de Luminy, 13009 Marseille, France 

Corresponding author.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Introduction

Kinematic alignment (KA) technique is an alternative technique for positioning a TKA, which aims a patient-specific implant positioning in order to reproduce the pre-arthritic knee anatomy. Because reliability in implant positioning is of interest to obtain reproducible good functional results, our study tests the hypothesis that the medial and lateral distal and posterior positions of the planned and surgically implanted kinematically aligned femoral component are similar.

Methods

Preoperative knee magnetic resonance imaging (MRI) and postoperative knee computed tomography (CT) of 13 patients implanted with a KA Persona® TKA (Zimmer, Warsaw, USA) using manual instrumentation (kinematically-aligned TKA procedure pack®, Zimmer Biomet, Warsaw, USA) were segmented to create 3D femoral models. The kinematic alignment position of the femoral component was planned on the 3D model created from the preoperative MRI. Differences in the positions of the planned and surgically implanted kinematically-aligned femoral component were determined with in-house analysis software.

Results

The average differences between the medial and lateral distal and posterior positions of the planned and surgically implanted kinematically-aligned femoral component were inferior to 1mm and no statistically significant. In terms of variability, 62% (8/13) of performed implants matched all four positions within 1.5mm, and the maximum difference was 3mm.

Conclusion

In this small series, intraoperative kinematic positioning of the femoral component with the specific manual instrumentation closely matched the planned position, which suggests that this technique reliably aligned the flexion-extension axis of the femoral component to the cylindrical axis.

Level of evidence

Level 3.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Total Knee Arthroplasty, Kinematic alignment, Reproducibility, Positioning, Reliability, Cylindrical axis


Mappa


© 2017  Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 103 - N° 7

P. 1069-1073 - novembre 2017 Ritorno al numero
Articolo precedente Articolo precedente
  • Mechanical alignment technique for TKA: Are there intrinsic technical limitations?
  • C. Rivière, F. Iranpour, E. Auvinet, A. Aframian, K. Asare, S. Harris, J. Cobb, S. Parratte
| Articolo seguente Articolo seguente
  • Does curettage–cement packing for treating giant cell tumors at the knee lead to osteoarthritis?
  • A. Caubère, S. Harrosch, M. Fioravanti, G. Curvale, A. Rochwerger, J.-C. Mattei

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.