Abbonarsi

Differentiation between idiopathic granulomatous mastitis and malignant breast lesions using strain ratio on ultrasonic elastography - 15/11/17

Doi : 10.1016/j.diii.2017.06.009 
B. Yağcı a, I. Erdem Toslak a, b, , B. Çekiç a, M. Öz a, B.R. Karakaş c, M. Akdemir d, S. Yıldız a, D. Süren e, D. Bova b
a Department of Radiology, Antalya Training and Research Hospital, Health Sciences University, Antalya, Turkey 
b Department of Radiology, Loyola University Medical Center, Maywood, Illinois, USA 
c Department of General Surgery, Antalya Training and Research Hospital, Health Sciences University, Antalya, Turkey 
d Department of Public Health, Akdeniz University Medical School,Antalya, Turkey 
e Department of Pathology, Antalya Training and Research Hospital, Health Sciences University, Antalya, Turkey 

Corresponding author at: Department of Radiology, Antalya Training and Research Hospital, Health Sciences University, Antalya, Turkey.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
Articolo gratuito.

Si connetta per beneficiarne

Abstract

Purpose

The goal of this study was to investigate the strain elastography imaging characteristics of idiopathic granulomatous mastitis (IGM) and compare strain ratio values of IGM with those of breast cancer.

Material and methods

Twenty-three consecutive women with IGM (mean age, 37.9±6.6 [SD] years; range: 26–52 years) and 45 women with malignant breast tumor (mean age, 52.8±12.0 [SD], range, 32–77 years) who had been scheduled for ultrasound-guided core biopsy were recruited to the study. All had ultrasonography with elastography before biopsy. The strain ratios of lesions were calculated using surrounding normal breast tissue as the reference in both groups and compared between the two groups. Receiver-operating-characteristics (ROC) curves were formed. Sensitivity, specificity, cut-off, and area under curve (AUC) values were calculated.

Results

The mean strain ratio on sonoelastography was 1.5±0.8 (SD) (range: 0.2–4.0) for IGM and 5.3±5.2 (SD) (range: 1.4–33) for malignant lesions. Strain ratio values in IGM lesions were significantly lower than in malignant lesions (P˂0.05). ROC test yielded an AUC value of 0.939 (95% confidence interval, 0.882–0.995; P<0.0001). Optimal cut-off value for strain ratio value was 2.5 yielding 87% sensitivity and 96% specificity for the diagnosis of IGM.

Conclusion

Sonoelastographic strain ratio contributes to differentiate IGM from malignant breast lesions, thus has potential to influence clinical decision making for further biopsies.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Ultrasonography, Elastography, Strain ratio, Granulomatous mastitis, Breast cancer

Abbreviations : UE, IGM, SR


Mappa


© 2017  Editions françaises de radiologie. Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 98 - N° 10

P. 685-691 - ottobre 2017 Ritorno al numero
Articolo precedente Articolo precedente
  • Evaluation of MR imaging-targeted biopsies of the prostate in biopsy-naïve patients. A single centre study
  • J. Garcia Bennett, J.C. Vilanova, J. Gumà Padró, D. Parada, A. Conejero
| Articolo seguente Articolo seguente
  • Diagnostic value of 18F-FDG-PET/CT for the follow-up and restaging of soft tissue sarcomas in adults
  • T.W. Kassem, O. Abdelaziz, S. Emad-Eldin

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.