Abbonarsi

Dynamic arterial elastance obtained using arterial signal does not predict an increase in arterial pressure after a volume expansion in the operating room - 29/11/17

Doi : 10.1016/j.accpm.2017.05.001 
Romain Lanchon a , Karine Nouette-Gaulain a, b , Laurent Stecken c , Musa Sesay a , Jean-Yves Lefrant d , Matthieu Biais a, e, f,
a Service d’anesthésie réanimation 3, CHU de Bordeaux, 33000 Bordeaux, France 
b INSERM, U12-11, laboratoire de maladies rares : génétique et métabolisme (MRGM), université de Bordeaux, 33000 Bordeaux, France 
c Pôle des urgences adultes, CHU de Bordeaux, 33000 Bordeaux, France 
d Service des réanimations et service de recherche clinique en anesthésie réanimation, division anesthésie, réanimation, douleur, urgences, CHU de Nîmes, université de Montpellier, place du Professeur-Robert-Debré, 30029 Nîmes cedex 9, France 
e INSERM, adaptation cardiovasculaire à l’ischémie, U1034, 33600 Pessac, France 
f Adaptation cardiovasculaire à l’ischémie, U1034, université de Bordeaux, 33600 Pessac, France 

Corresponding author. Department of anaesthesiology and Critical Care III, hôpital Pellegrin, CHU de Bordeaux, 33076 Bordeaux cedex, France.Department of anaesthesiology and Critical Care III, hôpital Pellegrin, CHU de Bordeaux, 33076 Bordeaux cedex, France.

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

pagine 6
Iconografia 3
Video 0
Altro 0

Abstract

Introduction

Dynamic arterial elastance (Eadyn) is defined as the ratio between pulse pressure variations (PPV) and stroke volume variations (SVV). Eadyn has been proposed to predict an increase in mean arterial pressure (MAP) after volume expansion with conflicting results. The aim of the present study was to test the reliability of Eadyn in hypotensive patients (MAP<65mmHg) in the operating room (OR).

Patients and methods

The study pooled data from 51 patients. They were included after the induction of anaesthesia and before skin incision. Eadyn, MAP and stroke volume (FloTrac™, Vigileo™, Edwards Lifesciences, Irvine,CA) were recorded before and after volume expansion (500mL starch 6% given over 10minutes). Pressure-responders were defined as an increase MAP15% after volume expansion. Changes in MAP were predicted using the area under the curves (AUC) with their 95% Confidence Interval (95%CI) derived from Receiver Operating Characteristic curves.

Results

Seventeen patients responded to volume expansion. Heart rate, PPV, SVV and Eadyn were similar between pressure-responders and non-responders. Baseline values of stroke volume, cardiac output and MAP were lower in responders. Volume expansion induced significant variations in stroke volume, cardiac output, SVV and PPV, but not in Eadyn. Baseline Eadyn failed to predict MAP increase (AUC=0.53, 95%CI=0.36–0.70, P>0.05) and was not correlated with volume expansion-induced changes in MAP (P>0.05). In preload responsive patients (changes in SV15% after volume expansion, n=24), the AUC was 0.54 (95%CI=0.29–0.78; P>0.05).

Conclusion

In the present study performed in the OR and in hypotensive patients, Eadyn obtained using arterial signal was unable to predict an increase in MAP after volume expansion.

Il testo completo di questo articolo è disponibile in PDF.

Keywords : Arterial pressure, Stroke volume variation, Pulse pressure variation, Arterial elastance, Volume expansion


Mappa


© 2017  Société française d’anesthésie et de réanimation (Sfar). Pubblicato da Elsevier Masson SAS. Tutti i diritti riservati.
Aggiungere alla mia biblioteca Togliere dalla mia biblioteca Stampare
Esportazione

    Citazioni Export

  • File

  • Contenuto

Vol 36 - N° 6

P. 377-382 - dicembre 2017 Ritorno al numero
Articolo precedente Articolo precedente
  • A comparison of balanced and unbalanced crystalloid solutions in surgery patient outcomes
  • Tomas Kuca, Michael B. Butler, Mete Erdogan, Robert S. Green
| Articolo seguente Articolo seguente
  • The clinical impact and prevalence of emergency point-of-care ultrasound: A prospective multicenter study
  • Xavier Bobbia, Laurent Zieleskiewicz, Christophe Pradeilles, Chloé Hudson, Laurent Muller, Pierre Géraud Claret, Marc Leone, Jean-Emmanuel de La Coussaye, Winfocus France Group

Benvenuto su EM|consulte, il riferimento dei professionisti della salute.
L'accesso al testo integrale di questo articolo richiede un abbonamento.

Già abbonato a @@106933@@ rivista ?

@@150455@@ Voir plus

Il mio account


Dichiarazione CNIL

EM-CONSULTE.COM è registrato presso la CNIL, dichiarazione n. 1286925.

Ai sensi della legge n. 78-17 del 6 gennaio 1978 sull'informatica, sui file e sulle libertà, Lei puo' esercitare i diritti di opposizione (art.26 della legge), di accesso (art.34 a 38 Legge), e di rettifica (art.36 della legge) per i dati che La riguardano. Lei puo' cosi chiedere che siano rettificati, compeltati, chiariti, aggiornati o cancellati i suoi dati personali inesati, incompleti, equivoci, obsoleti o la cui raccolta o di uso o di conservazione sono vietati.
Le informazioni relative ai visitatori del nostro sito, compresa la loro identità, sono confidenziali.
Il responsabile del sito si impegna sull'onore a rispettare le condizioni legali di confidenzialità applicabili in Francia e a non divulgare tali informazioni a terzi.


Tutto il contenuto di questo sito: Copyright © 2026 Elsevier, i suoi licenziatari e contributori. Tutti i diritti sono riservati. Inclusi diritti per estrazione di testo e di dati, addestramento dell’intelligenza artificiale, e tecnologie simili. Per tutto il contenuto ‘open access’ sono applicati i termini della licenza Creative Commons.